Sheet 10: G-C-14

CC-Schleppflex® PVC-C-573
Superflex shielded
Applications: 14AWG (2,50 mm²) Stranding: VDE 0295, class 6 (140 x 0,15 mm)
Power supply chains Part Numbers cond. O.D. inches O.D. mm Part Numbers cond. O.D. inches O.D. mm
Electical Equipments 573-14-03 3 0.46 11.5 573-14-12 12 0.79 20.0
UV, Oil and Cooling liquid resistant 573-14-04 4 0.50 12.7
Control devices 573-14-05 5 0.55 13.9
Whenever electrical interference 573-14-07 7 0.66 16.8
distorts signal transmission. 12AWG (4,00 mm²) Stranding: VDE 0295, class 6 (224 x 0,15 mm)
Specifications: Part Numbers cond. O.D. inches O.D. mm Part Numbers cond. O.D. inches O.D. mm
According to VDE 0245/0281 573-12-03 3 0.52 13.0 573-12-07 7 0.77 19.5
UL 2587/CSA AWM I A/B, II A.B FT1 573-12-04 4 0.59 14.8
Construction: 573-12-05 5 0.65 16.4
Conductors: 10AWG (6,00 mm²) Stranding: VDE 0295, class 6 (192 x 0,20 mm)
Fine bare copper strands acc. Part Numbers cond. O.D. inches O.D. mm Part Numbers cond. O.D. inches O.D. mm
to VDE 0295, class 6, with 573-10-04 4 0.67 16.9
PVC insulation 8AWG (10,00 mm²) Stranding: VDE 0295, class 6 (320 x 0,20 mm)
Color code: Part Numbers cond. O.D. inches O.D. mm Part Numbers cond. O.D. inches O.D. mm
black conductors with white 573-08-04 4 0.84 21.3
consec. numbers, cables with 6AWG (16,00 mm²) Stranding: VDE 0295, class 6 (512 x 0,20 mm)
three or more conductors Part Numbers cond. O.D. inches O.D. mm Part Numbers cond. O.D. inches O.D. mm
with green/yellow ground wire 573-06-04 4 1.02 25.9
in the outer layer
Stranding:
cores twisted in layers
with very short lay lengths
fleece around cores, and inner
jacket gray plus common shield
Jacket:
Outer jacket black, flame retardant
and self-extinguishing, common
braided shield between jackets
Technical Data:
Rated voltage:
600 Volt
Test voltage:
4,000 volt
Bending radius:
fixed: 5 x diameter
flexible app.: 7.5 x diameter
Temperature range:
fixed: 23°F to 194°F
flex.: 23°F to 194°F