RDE Connects

rde Connectors & Cables Inc.
5277 NW 108 Ave. Sunrise, FL 33351

Sheet 2: G-D-02

CC-Schleppflex® PUR-575
Superflex
Applications: 20AWG (0,50 mm²) Stranding: VDE 0295, class 6 (28 x 0,15 mm)
Power supply chains Part Numbers cond. O.D. inches O.D. mm Part Numbers cond. O.D. inches O.D. mm
Electical Equipments 575-0005-003 3 0.26 6.6 575-0005-018 18 0.48 12.2
Harsh environment 575-0005-004 4 0.28 7.0 575-0005-025 25 0.62 15.8
Control devices 575-0005-005 5 0.29 7.4 575-0005-034 34 0.68 17.1
Damp and wet areas 575-0005-007 7 0.34 8.6
Moving devices 575-0005-012 12 0.40 10.1
Specifications: 18AWG (0,75 mm²) Stranding: VDE 0295, class 6 (42 x 0,15 mm)
According to VDE Part Numbers cond. O.D. inches O.D. mm Part Numbers cond. O.D. inches O.D. mm
0245, 0281 575-0007-003 3 0.27 6.8 575-0007-016 16 0.50 12.6
Construction: 575-0007-004 4 0.29 7.4 575-0007-018 18 0.53 13.5
Conductors: 575-0007-005 5 0.32 8.0 575-0007-025 25 0.66 16.7
Fine bare copper strands acc. 575-0007-007 7 0.38 9.5 575-0007-034 34 0.77 19.4
to VDE 0295, class 6, with 575-0007-012 12 0.45 11.3
PVC insulation 17AWG (1,00 mm²) Stranding: VDE 0295, class 6 (56 x 0,15 mm)
Color code: Part Numbers cond. O.D. inches O.D. mm Part Numbers cond. O.D. inches O.D. mm
black conductors with white 575-0010-003 3 0.29 7.2 575-0010-025 25 0.71 18.0
consec. numbers, cables with 575-0010-004 4 0.31 7.8 575-0010-034 34 0.78 19.8
three or more conductors 575-0010-005 5 0.34 8.5 575-0010-041 41 0.85 21.5
with green/yellow ground 575-0010-007 7 0.41 10.2 575-0010-050 50 0.91 23.1
wire in the outer layer 575-0010-012 12 0.48 12.2 575-0010-065 65 1.04 26.5
Stranding: 575-0010-016 16 0.55 13.8
cores twisted in layers 575-0010-018 18 0.58 14.7
with very short lay lengths 16AWG (1,50 mm²) Stranding: VDE 0295, class 6 (84 x 0,15 mm)
and fleece around cores Part Numbers cond. O.D. inches O.D. mm Part Numbers cond. O.D. inches O.D. mm
Jacket: 575-0015-003 3 0.32 8.0 575-0015-025 25 0.80 20.2
PUR jacket gray 575-0015-004 4 0.34 8.7 575-0015-034 34 0.86 21.9
flame retardant and self- 575-0015-005 5 0.39 9.7 575-0015-042 42 0.94 23.8
extinguishing, resistant against 575-0015-007 7 0.47 11.8 575-0015-050 50 1.02 26.0
mineral oils, hydrolysis, microbes 575-0015-012 12 0.54 13.7 575-0015-061 61 1.19 30.2
Technical Data: 575-0015-016 16 0.63 15.9
Rated voltage: 575-0015-018 18 0.65 16.5
300/500 Volt 14AWG (2,50 mm²) Stranding: VDE 0295, class 6 (140 x 0,15 mm)
Test voltage: Part Numbers cond. O.D. inches O.D. mm Part Numbers cond. O.D. inches O.D. mm
3,000 Volt 575-0025-003 3 0.38 9.6 575-0025-014 14 0.72 18.1
Bending radius: 575-0025-004 4 0.42 10.7 575-0025-018 18 0.85 21.5
fixed: 5 x diameter 575-0025-005 5 0.48 12.0 575-0025-025 25 1.05 26.6
flexible app.: 7.5 x diameter 575-0025-007 7 0.57 14.4
Temperature range: 575-0025-012 12 0.67 16.9
fixed: 23°F to 158°F
flex.: 23°F to 158°F