RDE Connects

rde Connectors & Cables Inc.
5277 NW 108 Ave. Sunrise, FL 33351

Sheet 8: G-D-15

CC-Schleppflex® PUR-C-576-UL
Superflex shielded
Applications: 20AWG (0.50 mm²) Stranding: VDE 0295, class 6 (28 x 0.15 mm)
Power supply chains Part Numbers cond. O.D. inches O.D. mm Part Numbers cond. O.D. inches O.D. mm
Control devices 576-20-03 3 0.36 9.1 576-20-12 12 0.55 14.0
Whenever elecrical interference 576-20-04 4 0.39 9.8 576-20-18 18 0.64 16.2
distorts signal transmission. 576-20-05 5 0.41 10.4 576-20-25 25 0.76 19.3
Specifications: 576-20-07 7 0.46 11.6 576-20-34 34 0.85 21.5
According to VDE 0281, 0245 19AWG (0.75 mm²) Stranding: VDE 0295, class 6 (42 x 0.15 mm)
UL style 10012/20234 Part Numbers cond. O.D. inches O.D. mm Part Numbers cond. O.D. inches O.D. mm
CSA AWM I A/B, II A/B FT 1 576-19-03 3 0.37 9.2 576-19-16 16 0.63 16.0
Construction: 576-19-04 4 0.41 10.2 576-19-18 18 0.72 18.2
Conductors: 576-19-05 5 0.43 10.9 576-19-25 25 0.83 21.0
Fine bare copper strands acc. 576-19-07 7 0.50 12.7 576-19-34 34 0.94 23.8
to VDE 0295, class 6, with 576-19-12 12 0.59 14.8
PVC insulation 18AWG (1.00 mm²) Stranding: VDE 0295, class 6 (56 x 0.15 mm)
Color code: Part Numbers cond. O.D. inches O.D. mm Part Numbers cond. O.D. inches O.D. mm
black cond. with white consec. 576-18-03 3 0.37 9.4 576-18-16 16 0.68 17.2
numbers, cables with three or 576-18-04 4 0.41 10.4 576-18-18 18 0.75 18.9
more cond. with yellow/green 576-18-05 5 0.44 11.2 576-18-25 25 0.87 22.0
ground wire in the outer layer 576-18-07 7 0.52 13.2 576-18-34 34 0.97 24.5
Stranding: 576-18-12 12 0.62 15.6 576-18-41 41 1.05 26.7
cores twisted in layers with 16AWG (1.50 mm²) Stranding: VDE 0295, class 6 (84 x 0.15 mm)
very short lay lengths and fleece Part Numbers cond. O.D. inches O.D. mm Part Numbers cond. O.D. inches O.D. mm
around cores, plus common 576-16-03 3 0.42 10.6 756-16-16 16 0.74 18.8
shield and inner jacket PVC 576-16-04 4 0.45 11.4 576-16-18 18 0.77 19.6
Jacket: 576-16-05 5 0.49 12.3 576-16-25 25 0.93 23.6
outer PUR jacket, gray 576-16-07 7 0.56 14.1 576-16-34 34 1.06 27.0
flame retardant and self- 576-16-12 12 0.68 17.2 576-16-50 50 1.26 32.0
extinguishing, resistant against 14AWG (2.50 mm²) Stranding: VDE 0295, class 6 (140 x 0.15 mm)
minaral oils, hydrolysis and Part Numbers cond. O.D. inches O.D. mm Part Numbers cond. O.D. inches O.D. mm
microbes 576-14-03 3 0.50 12.6 576-14-07 7 0.67 16.9
Technical Data: 576-14-04 4 0.53 13.5 576-14-12 12 0.84 21.2
Rated voltage: 576-14-05 5 0.59 15.0 576-14-18 18 0.93 23.6
600 Volt 12AWG (4.00 mm²) Stranding: VDE 0295, class 6 (224 x 0.15 mm)
Test voltage: Part Numbers cond. O.D. inches O.D. mm Part Numbers cond. O.D. inches O.D. mm
4,000 Volt 576-12-04 4 0.63 16.0 576-12-07 7 0.78 19.8
Bending radius: 10AWG (6.00 mm²) Stranding: VDE 0295, class 6 (192 x 0.20 mm)
fixed: 5 x diameter Part Numbers cond. O.D. inches O.D. mm Part Numbers cond. O.D. inches O.D. mm
flexible app.: 7.5 x diameter 576-10-04 4 0.70 17.7 576-10-07 7 0.93 23.6
Temperature range: 8AWG (10.00 mm²) Stranding: VDE 0295, class 6 (320 x 0.20 mm)
fixed: 23°F to 176°F Part Numbers cond. O.D. inches O.D. mm Part Numbers cond. O.D. inches O.D. mm
flex.: 23°F to 176°F 576-08-04 4 0.71 18.0