RDE Connects

rde Connectors & Cables Inc.
5277 NW 108 Ave. Sunrise, FL 33351

Sheet 4: G-G-06

CC-BUS-Schleppflex® CAN-PUR-C-94
with filler if necessary Superflex shielded halogen-free
Applications: Pairs with 0.34 mm² (22AWG) Stranding: 42 x 0.10 mm
Fieldbus Systems Part Numbers no. of pairs O.D. inches O.D. mm Fieldbus
Cooling liquid and oil resistant 94-034-016 1 pair 0.24 5.9 CAN Bus
Power supply chains 94-034-026 2 pairs 0.25 6.2 up to 1 MBaud
Max. bitrate is up to 1 MBit/s. With increasing
segment length larger cross sections should Pairs with 0.50 mm² (20AWG) Stranding: 28 x 0.15 mm
be used. Part Numbers no. of pairs O.D. inches O.D. mm Fieldbus
non-adhesive 94-050-016 1 pair 0.28 7.0 CAN Bus
Specifications: 94-050-026 2 pairs 0.28 7.0 up to 1 MBaud
According to ISO 11898
cUL style 20963, 20549
Construction:
Conductors: ISO 11898 recommends the following:
Fine bare copper strands acc. to
VDE 0295, class 6, with PP/PE insulation Segment length Cross-section from.... to Max. bitrate at...
Color code: up to 40 m (131 ft.) 0.22 mm 0.34 mm 1 MBit/s 40 m (131 ft.)
DIN 47100 40-300 m (131-984 ft) 0.34 mm 0.60 mm 500 kBit/s 100 m (328 ft)
300-600m(984-1968ft) 0.50 mm 0.60 mm 100 kBit/s 500 m (1640 ft)
Stranding: 600-1000m(1968-3280ft) 0.75 mm 0.80 mm 50 kBit/s 1000 m(3280ft)
cores twisted in pairs, two pairs laid in
star quad, bandage, common braided
shield between pairs and jacket
Jacket:
PUR jacket violet, flame retardant
and self-extinguishing, non-adhesive,
resistant to hydrolysis and microbes
Technical Data:
Rated voltage:
300 Volt, not for power applications
Test voltage:
1,000 Volt
Bending radius:
fixed: 10 x diameter
flexible app.: 15 x diameter
Temperature range:
fixed: -40°F to 176°F
flex.: -22°F to 158°F