Sheet 1: G-A-30

Shielded - PVC - Control - Cable - JZ - CY - 168
Applications: 20AWG (0.5 mm²) Stranding: VDE 295, class 5 (16 x 0,2 mm)
Machining Centers Part Numbers cond. O.D. inches O.D. mm Part Numbers cond. O.D. inches O.D. mm
Control Panels 168-20-02 2 0.33 8.3 168-20-18 18 0.64 16.2
Control Systems 168-20-03 3 0.34 8.5 168-20-25 25 0.79 20.0
Machines 168-20-04 4 0.36 9.2 168-20-34 34 0.91 23.0
Electrical Equipments 168-20-05 5 0.40 10.0 168-20-41 41 0.95 24.0
Whenever electrical interference 168-20-07 7 0.45 11.4
distorts signal transmission. 168-20-09 9 0.46 11.6
Specifications: 168-20-12 12 0.57 14.5
UL: AWM-Style 1012/2587 19AWG (0.75 mm²) Stranding: VDE 295, class 5 (24 x 0,2 mm)
CSA: AWM I A/B, II A/B FT 1 Part Numbers cond. O.D. inches O.D. mm Part Numbers cond. O.D. inches O.D. mm
Construction: 168-19-02 2 0.34 8.6 168-19-18 18 0.67 16.9
Conductors: 168-19-03 3 0.36 9.3 168-19-25 25 0.85 21.5
bare copper strands acc. to 168-19-04 4 0.40 10.2 168-19-34 34 0.93 23.7
VDE 0295, class 5, with PVC 168-19-05 5 0.43 10.9 168-19-41 41 0.97 24.5
insulation 168-19-07 7 0.51 12.9
Color code: 168-19-09 9 0.53 13.4
black conductors with consec. 168-19-12 12 0.56 14.3
numbers, cables with three or 18AWG (1.00 mm²) Stranding: VDE 295, class 5 (32 x 0,2 mm)
more conductors with green/ Part Numbers cond. O.D. inches O.D. mm Part Numbers cond. O.D. inches O.D. mm
yellow ground wire in the outer 168-18-02 2 0.35 8.9 168-18-12 12 0.66 16.8
layer 168-18-03 3 0.37 9.5 168-18-18 18 0.71 18.0
Stranding: 168-18-04 4 0.40 10.1 168-18-25 25 0.87 22.00
cores twisted in layers 168-18-05 5 0.44 11.1 168-18-34 34 1.01 25.6
Jacket: 168-18-07 7 0.52 13.2 168-18-41 41 1.05 26.6
Inner jacket PVC gray, plus 168-18-09 9 0.60 15.1
common braided shield with PVC 16AWG (1.50 mm²) Stranding: VDE 295, class 5 (30 x 0,25 mm)
outer jacket gray, self-extinguising, Part Numbers cond. O.D. inches O.D. mm Part Numbers cond. O.D. inches O.D. mm
flame retardant acc. IEC 332-1 and 168-16-02 2 0.40 10.2 168-16-18 18 0.82 20.8
oil restistant. 168-16-03 3 0.43 10.9 168-16-25 25 1.06 26.8
Technical Data: 168-16-04 4 0.47 11.9 168-16-34 34 1.16 29.5
Rated voltage: 168-16-05 5 0.52 13.2 168-16-41 41 1.22 30.7
600 Volt 168-16-07 7 0.62 15.7
Test voltage: 168-16-09 9 0.67 17.0
3,000 Volt 168-16-12 12 0.74 18.7
Bending radius: 14AWG (2.50 mm²) Stranding: VDE 295, class 5 (50 x 0,25 mm)
fixed: 5 x diameter Part Numbers cond. O.D. inches O.D. mm Part Numbers cond. O.D. inches O.D. mm
flexible app.: 15 x diameter 168-14-02 2 0.46 11.6 168-14-09 9 0.80 20.4
Temperature range: 168-14-03 3 0.48 12.1 168-14-12 12 0.87 22.0
fixed: -40°F to 194°F 168-14-04 4 0.53 13.4 168-14-18 18 1.00 25.3
flex.: 23°F to 194°F 168-14-05 5 0.57 14.4
168-14-07 7 0.69 17.5


Sheet 2: G-A-31

Shielded - PVC - Control - Cable - JZ - CY - 168
Applications: 12AWG (4.00 mm²) Stranding: VDE 295, class 5 (56 x 0,3 mm)
Machining Centers Part Numbers cond. O.D. inches O.D. mm Part Numbers cond. O.D. inches O.D. mm
Control Panels 168-12-03 3 0.50 12.8 168-12-07 7 0.69 17.4
Control Systems 168-12-04 4 0.53 13.5
Machines 168-12-05 5 0.58 14.6
Electrical Equipments 10AWG (6.00 mm²) Stranding: VDE 295, class 5 (84 x 0,3 mm)
Whenever electrical interference Part Numbers cond. O.D. inches O.D. mm Part Numbers cond. O.D. inches O.D. mm
distorts signal transmission. 168-10-03 3 0.66 16.6 168-10-07 7 0.82 20.9
Specifications: 168-10-04 4 0.69 17.5
UL: AWM-Style 1012/2587 168-10-05 5 0.73 18.5
CSA: AWM I A/B, II A/B FT 1 8AWG (10.00 mm²) Stranding: VDE 295, class 5 (80 x 0,4 mm)
Construction: Part Numbers cond. O.D. inches O.D. mm Part Numbers cond. O.D. inches O.D. mm
Conductors: 168-08-03 3 0.68 17.2 168-08-07 7 1.02 26
bare copper strands acc. to 168-08-04 4 0.80 20.4
VDE 0295, class 5, with PVC 168-08-05 5 0.87 22.0
insulation 6AWG (16.00 mm²) Stranding: VDE 295, class 5 (128 x 0,4 mm)
Color code: Part Numbers cond. O.D. inches O.D. mm Part Numbers cond. O.D. inches O.D. mm
black conductors with consec. 168-06-03 3 0.93 23.6 168-06-07 7 1.27 32.0
numbers, cables with three or 168-06-04 4 1.02 25.8
more conductors with green/ 168-06-05 5 1.15 29.0
yellow ground wire in the outer 4AWG (25.00 mm²) Stranding: VDE 295, class 5 (200 x 0,4 mm)
layer Part Numbers cond. O.D. inches O.D. mm Part Numbers cond. O.D. inches O.D. mm
Stranding: 168-04-03 3 1.12 28.0 168-04-07 7 1.54 39.00
cores twisted in layers 168-04-04 4 1.19 30.2
Jacket: 168-04-05 5 1.35 34.0
Inner jacket PVC gray, plus 2AWG (35.00 mm²) Stranding: VDE 295, class 5 (280 x 0,4 mm)
common braided shield with PVC Part Numbers cond. O.D. inches O.D. mm Part Numbers cond. O.D. inches O.D. mm
outer jacket gray, self-extinguising, 168-02-03 3 1.19 30.0 168-02-05 5 1.46 37
flame retardant acc. IEC 332-1 and 168-02-04 4 1.27 32.0
oil restistant.
Technical Data:
Rated voltage:
600 Volt
Test voltage:
3,000 Volt
Bending radius:
fixed: 5 x diameter
flexible app.: 15 x diameter
Temperature range:
fixed: -40°F to 194°F
flex.: 23°F to 194°F