RDE Connects

rde Connectors & Cables Inc.
5277 NW 108 Ave. Sunrise, FL 33351


Overview

G-C-01 G-C-02 G-C -03 G-C-04 G-C-05 G-C-10 G-C-11 G-C-12 G-C-13 G-C-14


Sheet 1: G-C-01

CC-Schleppflex® P a g e s
All CC-Schleppflex® Cables from ConCab are based on the new DESINA standards.

Sheet 2: G-C-02

CC-Schleppflex® PVC-570
Superflex
Applications: 26AWG (0,14 mm²) Stranding: VDE 0295, class 6 (18 x 0,10 mm)
Power supply chains Part Numbers cond. O.D. inches O.D. mm Part Numbers cond. O.D. inches O.D. mm
Electical Equipments 570-0001-002 2 0.16 4.0 570-0001-012 12 0.29 7.3
Sensor technology 570-0001-003 3 0.18 4.5 570-0001-014 14 0.30 7.5
Control devices 570-0001-004 4 0.19 4.8 570-0001-018 18 0.32 8.0
Damp and wet areas 570-0001-005 5 0.20 5.1 570-0001-025 25 0.37 9.5
Moving devices 570-0001-007 7 0.25 6.2
Specifications: 570-0001-010 10 0.28 7.2
According to VDE 24AWG (0,25 mm²) Stranding: VDE 0295, class 6 (32 x 0,10 mm)
0281, 0812 Part Numbers cond. O.D. inches O.D. mm Part Numbers cond. O.D. inches O.D. mm
570-0002-002 2 0.18 4.5 570-0002-012 12 0.33 8.3
Construction: 570-0002-003 3 0.19 4.9 570-0002-014 14 0.34 8.5
Conductors: 570-0002-004 4 0.21 5.3 570-0002-018 18 0.37 9.5
Fine bare copper strands acc. 570-0002-005 5 0.24 6.2 570-0002-025 25 0.44 11.0
to VDE 0295, class 6, with 570-0002-007 7 0.28 7.0
PVC insulation 570-0002-010 10 0.33 8.2
Color code: 22AWG (0,34 mm²) Stranding: VDE 0295, class 6 (42 x 0,10 mm)
acc. to DIN 47100 Part Numbers cond. O.D. inches O.D. mm Part Numbers cond. O.D. inches O.D. mm
570-0003-002 2 0.20 5.0 570-0003-012 12 0.38 9.6
Stranding: 570-0003-003 3 0.23 5.7 570-0003-014 14 0.40 10.0
cores twisted in layers 570-0003-004 4 0.26 6.5 570-0003-018 18 0.43 11.0
with very short lay lengths 570-0003-005 5 0.28 7.0 570-0003-025 25 0.52 13.0
and fleece around cores 570-0003-007 7 0.32 8.0
570-0003-010 10 0.37 9.4
Jacket:
PVC jacket gray
flame retardant and self-
extinguishing
Technical Data:
Rated voltage:
250 Volt
Test voltage:
1,500 Volt
Bending radius:
fixed: 5 x diameter
flexible app.: 7.5 x diameter
Temperature range:
fixed: 23°F to 158°F
flex.: 23°F to 158°F


Sheet 3: G-C -03

CC-Schleppflex® PVC-570
Superflex
Applications: 20AWG (0,50 mm²) Stranding: VDE 0295, class 6 (28 x 0,15 mm)
Power supply chains Part Numbers cond. O.D. inches O.D. mm Part Numbers cond. O.D. inches O.D. mm
Electical Equipments 570-0005-002 2 0.21 5.3 570-0005-018 18 0.46 11.7
Sensor technology 570-0005-003 3 0.22 5.6 570-0005-025 25 0.54 13.7
Control devices 570-0005-004 4 0.25 6.4 570-0005-030 30 0.59 14.9
Damp and wet areas 570-0005-005 5 0.28 7.1 570-0005-034 34 0.64 16.1
Moving devices 570-0005-007 7 0.33 8.3 570-0005-042 42 0.72 18.6
Specifications: 570-0005-012 12 0.39 10.0 570-0005-050 50 0.73 18.6
According to VDE 570-0005-014 14 0.42 10.6
0245, 0812 18AWG (0,75 mm²) Stranding: VDE 0295, class 6 (42 x 0,15 mm)
Part Numbers cond. O.D. inches O.D. mm Part Numbers cond. O.D. inches O.D. mm
Construction: 570-0007-002 2 0.23 5.9 570-0007-018 18 0.52 13.2
Conductors: 570-0007-003 3 0.24 6.2 570-0007-025 25 0.63 15.9
Fine bare copper strands acc. 570-0007-004 4 0.28 7.2 570-0007-030 30 0.68 17.3
to VDE 0295, class 6, with 570-0007-005 5 0.31 7.9 570-0007-034 34 0.73 18.5
PVC insulation 570-0007-007 7 0.37 9.3 570-0007-042 42 0.75 19.0
Color code: 570-0007-012 12 0.44 11.2 570-0007-050 50 0.85 21.5
black conductors with white 570-0007-016 16 0.49 12.5
consec. numbers, cables with 17AWG (1,00 mm²) Stranding: VDE 0295, class 6 (56 x 0,15 mm)
three or more conductors Part Numbers cond. O.D. inches O.D. mm Part Numbers cond. O.D. inches O.D. mm
with green/yellow ground 570-0010-002 2 0.28 7.1 570-0010-018 18 0.60 15.2
wire in the outer layer 570-0010-003 3 0.29 7.4 570-0010-025 25 0.72 18.3
Stranding: 570-0010-004 4 0.32 8.1 570-0010-034 34 0.84 21.3
cores twisted in layers 570-0010-005 5 0.37 9.3 570-0010-041 41 0.91 23.1
with very short lay lengths 570-0010-007 7 0.44 11.1 570-0010-050 50 0.97 24.8
and fleece around cores 570-0010-012 12 0.51 12.8 570-0010-065 65 1.14 28.9
Jacket: 570-0010-014 14 0.54 13.6
PVC jacket gray 570-0010-016 16 0.57 14.4
flame retardant and self- 16AWG (1,50 mm²) Stranding: VDE 0295, class 6 (84 x 0,15 mm)
extinguishing Part Numbers cond. O.D. inches O.D. mm Part Numbers cond. O.D. inches O.D. mm
Technical Data: 570-0015-002 2 0.30 7.5 570-0015-034 34 0.90 22.7
Rated voltage: 570-0015-003 3 0.31 7.9 570-0015-041 41 0.98 24.7
300/500 Volt 570-0015-004 4 0.35 8.8 570-0015-042 42 0.98 24.7
Test voltage: 570-0015-005 5 0.39 9.9 570-0015-050 50 1.04 26.5
3,000 Volt 570-0015-007 7 0.47 11.8 570-0015-061 61 1.10 28.0
Bending radius: 570-0015-012 12 0.54 13.6 570-0015-065 65 1.22 31.0
fixed: 5 x diameter 570-0015-014 14 0.56 14.2
flexible app.: 7.5 x diameter 570-0015-016 16 0.60 15.3
Temperature range: 570-0015-018 18 0.65 16.2
fixed: 23°F to 158°F 570-0015-025 25 0.78 19.9
flex.: 23°F to 158°F 570-0015-030 30 0.83 21.0


Sheet 4: G-C-04

CC-Schleppflex® PVC-570
Superflex
Applications: 14AWG (2,50 mm²) Stranding: VDE 0295, class 6 (140 x 0,15 mm)
Power supply chains Part Numbers cond. O.D. inches O.D. mm Part Numbers cond. O.D. inches O.D. mm
Electical Equipments 570-0025-003 3 0.40 10.0 570-0025-014 14 0.73 18.6
Sensor technology 570-0025-004 4 0.44 11.1 570-0025-018 18 0.83 21.1
Control devices 570-0025-005 5 0.48 12.3 570-0025-025 25 0.99 25.0
Damp and wet areas 570-0025-007 7 0.61 15.5
Moving devices 570-0025-012 12 0.69 17.6
Specifications: 12AWG (4,00 mm²) Stranding: VDE 0295, class 6 (224 x 0,15 mm)
According to VDE Part Numbers cond. O.D. inches O.D. mm Part Numbers cond. O.D. inches O.D. mm
0245, 0812 570-0040-003 3 0.51 12.9 570-0040-007 7 0.72 18.1
570-0040-004 4 0.55 13.9
Construction: 570-0040-005 5 0.62 15.6
Conductors: 10AWG (6,00 mm²) Stranding: VDE 0295, class 6 (192 x 0,20 mm)
Fine bare copper strands acc. Part Numbers cond. O.D. inches O.D. mm Part Numbers cond. O.D. inches O.D. mm
to VDE 0295, class 6, with 570-0060-003 3 0.56 14.2 570-0060-007 7 0.86 21.8
PVC insulation 570-0060-004 4 0.65 16.5
Color code: 570-0060-005 5 0.75 18.9
black conductors with white 8AWG (10,00 mm²) Stranding: VDE 0295, class 6 (320 x 0,20 mm)
consec. numbers, cables with Part Numbers cond. O.D. inches O.D. mm Part Numbers cond. O.D. inches O.D. mm
three or more conductors 570-0100-003 3 0.73 18.5 570-0100-007 7 0.95 24.1
with green/yellow ground 570-0100-004 4 0.82 20.8
wire in the outer layer 570-0100-005 5 0.90 22.7
Stranding: 6AWG (16,00 mm²) Stranding: VDE 0295, class 6 (512 x 0,20 mm)
cores twisted in layers Part Numbers cond. O.D. inches O.D. mm Part Numbers cond. O.D. inches O.D. mm
with very short lay lengths 570-0160-004 4 0.95 24.2
and fleece around cores 570-0160-005 5 1.07 27.3
Jacket:
PVC jacket gray
flame retardant and self-
extinguishing
Technical Data:
Rated voltage:
300/500 Volt
Test voltage:
3,000 Volt
Bending radius:
fixed: 5 x diameter
flexible app.: 7.5 x diameter
Temperature range:
fixed: 23°F to 158°F
flex.: 23°F to 158°F


Sheet 5: G-C-05

CC-Schleppflex® PVC-570
with filler if necessary Superflex
Applications: 20AWG (0,50 mm²) Stranding: VDE 0295, class 6 (28 x 0,15 mm)
Power supply chains Part Numbers cond. O.D. inches O.D. mm Part Numbers cond. O.D. inches O.D. mm
Cooling liqid resistant 570-20-03 3 0.26 6.5 570-20-12 12 0.46 11.5
UV resistant, Oil resistant 570-20-04 4 0.29 7.4 570-20-18 18 0.53 13.3
Control devices 570-20-05 5 0.32 8.1 570-20-25 25 0.64 16.3
Damp and wet areas 570-20-07 7 0.37 9.4
Moving devices 19AWG (0,75 mm²) Stranding: VDE 0295, class 6 (42 x 0,15 mm)
Specifications: Part Numbers cond. O.D. inches O.D. mm Part Numbers cond. O.D. inches O.D. mm
According to VDE 570-19-02 2 0.27 6.9 570-19-12 12 0.48 12.2
0245, 0281, UL 2587 570-19-03 3 0.29 7.2 570-19-16 16 0.55 14.0
CSA: AMW I A/B, II A.B FT1 570-19-04 4 0.32 8.0 570-19-18 18 0.59 14.9
Construction: 570-19-05 5 0.34 8.6 570-19-25 25 0.70 17.7
Conductors: 570-19-07 7 0.41 10.4
Fine bare copper strands acc. 18AWG (1,00 mm²) Stranding: VDE 0295, class 6 (56 x 0,15 mm)
to VDE 0295, class 6, with Part Numbers cond. O.D. inches O.D. mm Part Numbers cond. O.D. inches O.D. mm
PVC insulation 570-18-02 2 0.30 7.5 570-18-16 16 0.57 14.5
Color code: 570-18-03 3 0.30 7.6 570-18-18 18 0.62 15.8
black conductors with white 570-18-04 4 0.33 8.2 570-18-25 25 0.75 18.9
consec. numbers, cables with 570-18-05 5 0.25 8.9 570-18-34 34 0.84 21.3
three or more conductors 570-18-07 7 0.43 10.8 570-18-41 41 0.95 24.1
with green/yellow ground 570-18-12 12 0.54 13.6 570-18-50 50 0.99 25.1
wire in the outer layer 16AWG (1,50 mm²) Stranding: VDE 0295, class 6 (84 x 0,15 mm)
Stranding: Part Numbers cond. O.D. inches O.D. mm Part Numbers cond. O.D. inches O.D. mm
cores twisted in layers 570-16-03 3 0.33 8.2 570-16-18 18 0.66 16.8
with very short lay lengths 570-16-04 4 0.36 9.0 570-16-25 25 0.82 20.8
and fleece around cores 570-16-05 5 0.40 10.0 570-16-34 34 0.92 23.3
Jacket: 570-16-07 7 0.47 11.9 570-16-42 42 1.04 26.5
PVC jacket black 570-16-12 12 0.57 14.4 570-16-50 50 1.09 27.6
flame retardant and self- 570-16-16 16 0.63 15.9
extinguishing 14AWG (2,50 mm²) Stranding: VDE 0295, class 6 (140 x 0,15 mm)
Technical Data: Part Numbers cond. O.D. inches O.D. mm Part Numbers cond. O.D. inches O.D. mm
Rated voltage: 570-14-03 3 0.42 10.5 570-14-07 7 0.60 15.1
600 Volt 570-14-04 4 0.45 11.4 570-14-12 12 0.74 18.8
Test voltage: 570-14-05 5 0.49 12.5
4,000 Volt 12AWG (4,00 mm²) Stranding: VDE 0295, class 6 (224 x 0,15 mm)
Bending radius: Part Numbers cond. O.D. inches O.D. mm Part Numbers cond. O.D. inches O.D. mm
fixed: 5 x diameter 570-12-03 3 0.45 11.4 570-12-05 5 0.56 14.3
flexible app.: 7.5 x diameter 570-12-04 4 0.51 12.8 570-12-07 7 0.69 17.4
Temperature range: 10AWG (6,00 mm²) Stranding: VDE 0295, class 6 (192 x 0,20 mm)
fixed: 23°F to 194°F Part Numbers cond. O.D. inches O.D. mm Part Numbers cond. O.D. inches O.D. mm
flex.: 23°F to 194°F 570-10-04 4 0.56 14.3


Sheet 6: G-C-10

CC-Schleppflex® PVC-C-573
with filler if necessary Superflex shielded
Applications: 26AWG (0,14 mm²) Stranding: VDE 0295, class 6 (18 x 0,10 mm)
Power supply chains Part Numbers cond. O.D. inches O.D. mm Part Numbers cond. O.D. inches O.D. mm
Electical Equipments 573-0001-002 2 0.20 5.0 573-0001-012 12 0.31 7.9
Sensor technology 573-0001-003 3 0.20 5.1 573-0001-014 14 0.32 8.1
Control devices 573-0001-004 4 0.21 5.3 573-0001-018 18 0.36 9.0
Whenever electrical interference 573-0001-005 5 0.23 5.8 573-0001-025 25 0.42 10.7
distorts signal transmission. 573-0001-007 7 0.27 6.8
Specifications: 573-0001-010 10 0.31 7.7
According to VDE 24AWG (0,25 mm²) Stranding: VDE 0295, class 6 (32 x 0,10 mm)
0281, 0812 Part Numbers cond. O.D. inches O.D. mm Part Numbers cond. O.D. inches O.D. mm
573-0002-002 2 0.22 5.4 573-0002-012 12 0.35 9.0
Construction: 573-0002-003 3 0.23 5.7 573-0002-014 14 0.36 9.2
Conductors: 573-0002-004 4 0.24 6.1 573-0002-018 18 0.39 9.9
Fine bare copper strands acc. 573-0002-005 5 0.27 6.7 573-0002-025 25 0.47 12.0
to VDE 0295, class 6, with 573-0002-007 7 0.30 7.6
PVC insulation 573-0002-010 10 0.45 8.8
Color code: 22AWG (0,34 mm²) Stranding: VDE 0295, class 6 (42 x 0,10 mm)
acc. to DIN 47100 Part Numbers cond. O.D. inches O.D. mm Part Numbers cond. O.D. inches O.D. mm
573-0003-002 2 0.24 6.0 573-0003-012 12 0.42 10.7
Stranding: 573-0003-003 3 0.25 6.3 573-0003-014 14 0.43 10.9
cores twisted in layers 573-0003-004 4 0.25 6.4 573-0003-018 18 0.46 11.5
with very short lay lengths 573-0003-005 5 0.30 7.5 573-0003-025 25 0.53 13.3
fleece around cores, and covered 573-0003-007 7 0.34 8.5
with common braided shield 573-0003-010 10 0.42 10.5
Jacket:
PVC jacket gray
flame retardant and self-
extinguishing
Technical Data:
Rated voltage:
250 Volt
Test voltage:
1,500 Volt
Bending radius:
fixed: 5 x diameter
flexible app.: 7.5 x diameter
Temperature range:
fixed: 23°F to 158°F
flex.: 23°F to 158°F


Sheet 7: G-C-11

CC-Schleppflex® PVC-C-573
with filler if necessary Superflex shielded
Applications: 20AWG (0,50 mm²) Stranding: VDE 0295, class 6 (28 x 0,15 mm)
Power supply chains Part Numbers cond. O.D. inches O.D. mm Part Numbers cond. O.D. inches O.D. mm
Electical Equipments 573-0005-002 2 0.30 7.5 573-0005-025 25 0.65 16.4
Sensor technology 573-0005-003 3 0.31 7.8 573-0005-030 30 0.69 17.4
Control devices 573-0005-004 4 0.33 8.2 573-0005-034 34 0.74 18.6
Whenever electrical interference 573-0005-005 5 0.37 9.3 573-0005-036 36 0.74 18.6
distorts signal transmission. 573-0005-007 7 0.43 10.7 573-0005-042 42 0.78 19.7
Specifications: 573-0005-012 12 0.49 12.4 573-0005-050 50 0.86 21.7
According to VDE 573-0005-014 14 0.51 12.8 573-0005-061 61 0.94 23.8
0245, 0281 573-0005-016 16 0.54 13.6
Construction: 573-0005-018 18 0.57 14.4
Conductors: 18AWG (0,75 mm²) Stranding: VDE 0295, class 6 (42 x 0,15 mm)
Fine bare copper strands acc. Part Numbers cond. O.D. inches O.D. mm Part Numbers cond. O.D. inches O.D. mm
to VDE 0295, class 6, with 573-0007-002 2 0.32 8.1 573-0007-018 18 0.63 15.9
PVC insulation 573-0007-003 3 0.33 8.4 573-0007-025 25 0.74 18.6
Color code: 573-0007-004 4 0.37 9.4 573-0007-030 30 0.79 19.9
black conductors with white 573-0007-005 5 0.41 10.3 573-0007-034 34 0.83 21.0
consec. numbers, cables with 573-0007-007 7 0.48 12.1 573-0007-036 36 0.83 21.0
three or more conductors 573-0007-012 12 0.54 13.6 573-0007-042 42 0.88 22.4
with green/yellow ground wire 573-0007-014 14 0.55 13.9 573-0007-050 50 0.93 23.7
in the outer layer 573-0007-016 16 0.59 15.0 573-0007-061 61 1.05 26.7
Stranding: 17AWG (1,00 mm²) Stranding: VDE 0295, class 6 (56 x 0,15 mm)
cores twisted in layers Part Numbers cond. O.D. inches O.D. mm Part Numbers cond. O.D. inches O.D. mm
with very short lay lengths 573-0010-002 2 0.39 9.9 573-0010-018 18 0.71 17.9
fleece around cores, and inner 573-0010-003 3 0.40 10.2 573-0010-025 25 0.83 21.0
jacket gray plus common shield 573-0010-004 4 0.43 10.9 573-0010-034 34 0.94 23.8
Jacket: 573-0010-005 5 0.46 11.7 573-0010-041 41 1.03 26.1
Outer jacket gray, flame retardant 573-0010-007 7 0.53 13.5 573-0010-050 50 1.10 27.9
and self-extinguishing, common 573-0010-012 12 0.61 15.5 573-0010-065 65 1.27 32.3
braided shield between jackets 573-0010-016 16 0.68 17.1
Technical Data: 16AWG (1,50 mm²) Stranding: VDE 0295, class 6 (84 x 0,15 mm)
Rated voltage: Part Numbers cond. O.D. inches O.D. mm Part Numbers cond. O.D. inches O.D. mm
300/500 Volt 573-0015-002 2 0.41 10.3
Test voltage: 573-0015-003 3 0.43 10.7
3,000 volt 573-0015-004 4 0.45 11.4
Bending radius: 573-0015-005 5 0.49 12.3
fixed: 5 x diameter 573-0015-007 7 0.57 14.5
flexible app.: 7.5 x diameter 573-0015-012 12 0.65 16.3
Temperature range: 573-0015-016 16 0.76 19.3
fixed: 23°F to 158°F 573-0015-018 18 0.80 20.3
flex.: 23°F to 158°F 573-0015-025 25 0.92 23.2


Sheet 8: G-C-12

CC-Schleppflex® PVC-C-573
with filler if necessary Superflex shielded
Applications: 14AWG (2,50 mm²) Stranding: VDE 0295, class 6 (140 x 0,15 mm)
Power supply chains Part Numbers cond. O.D. inches O.D. mm Part Numbers cond. O.D. inches O.D. mm
Electical Equipments 573-0025-003 3 0.51 12.8 573-0025-007 7 0.70 17.6
Sensor technology 573-0025-004 4 0.54 13.7
Control devices 573-0025-005 5 0.60 15.2
Whenever electrical interference 12AWG (4,00 mm²) Stranding: VDE 0295, class 6 (224 x 0,15 mm)
distorts signal transmission. Part Numbers cond. O.D. inches O.D. mm Part Numbers cond. O.D. inches O.D. mm
Specifications: 573-0040-003 3 0.61 15.5 573-0040-007 7 0.83 21.1
According to VDE 573-0040-004 4 0.64 16.6
0245, 0281 573-0040-005 5 0.71 17.9
Construction: 10AWG (6,00 mm²) Stranding: VDE 0295, class 6 (192 x 0,20 mm)
Conductors: Part Numbers cond. O.D. inches O.D. mm Part Numbers cond. O.D. inches O.D. mm
Fine bare copper strands acc. 573-0060-004 4 0.75 18.9 573-0060-007 7 0.94 23.7
to VDE 0295, class 6, with 573-0060-005 5 0.81 20.5
PVC insulation 8AWG (10,00 mm²) Stranding: VDE 0295, class 6 (320 x 0,20 mm)
Color code: Part Numbers cond. O.D. inches O.D. mm Part Numbers cond. O.D. inches O.D. mm
black conductors with white 573-0100-004 4 0.90 22.7
consec. numbers, cables with 573-0100-005 5 0.97 24.5
three or more conductors 6AWG (16,00 mm²) Stranding: VDE 0295, class 6 (512 x 0,20 mm)
with green/yellow ground wire Part Numbers cond. O.D. inches O.D. mm Part Numbers cond. O.D. inches O.D. mm
in the outer layer 573-0160-004 4 1.00 25.4
Stranding: 573-0160-005 5 1.10 28.0
cores twisted in layers
with very short lay lengths
fleece around cores, and inner
jacket gray plus common shield
Jacket:
Outer jacket gray, flame retardant
and self-extinguishing, common
braided shield between jackets
Technical Data:
Rated voltage:
300/500 Volt
Test voltage:
3,000 volt
Bending radius:
fixed: 5 x diameter
flexible app.: 7.5 x diameter
Temperature range:
fixed: 23°F to 158°F
flex.: 23°F to 158°F


Sheet 9: G-C-13

CC-Schleppflex® PVC-C-573
with filler if necessary Superflex shielded
Applications: 20AWG (0,50 mm²) Stranding: VDE 0295, class 6 (28 x 0,15 mm)
Power supply chains Part Numbers cond. O.D. inches O.D. mm Part Numbers cond. O.D. inches O.D. mm
Electical Equipments 573-20-03 3 0.35 8.8 573-20-25 25 0.73 18.5
UV, Oil and Cooling liquid resistant 573-20-04 4 0.36 9.0
Control devices 573-20-05 5 0.38 9.6
Whenever electrical interference 573-20-07 7 0.46 11.5
distorts signal transmission. 573-20-12 12 0.53 13.4
Specifications: 573-20-18 18 0.63 15.9
According to VDE 0245/0281 19AWG (0,75 mm²) Stranding: VDE 0295, class 6 (42 x 0,15 mm)
UL 2587/CSA AWM I A/B, II A.B FT1 Part Numbers cond. O.D. inches O.D. mm Part Numbers cond. O.D. inches O.D. mm
Construction: 573-19-02 2 0.36 9.0 573-19-16 16 0.67 17.0
Conductors: 573-19-03 3 0.38 9.7 573-19-18 18 0.71 18.0
Fine bare copper strands acc. 573-19-04 4 0.41 10.3 573-19-25 25 0.86 21.7
to VDE 0295, class 6, with 573-19-05 5 0.44 11.0
PVC insulation 573-19-07 7 0.52 13.0
Color code: 573-19-12 12 0.58 14.7
black conductors with white 18AWG (1,00 mm²) Stranding: VDE 0295, class 6 (56 x 0,15 mm)
consec. numbers, cables with Part Numbers cond. O.D. inches O.D. mm Part Numbers cond. O.D. inches O.D. mm
three or more conductors 573-18-02 2 0.37 9.2 573-18-25 25 0.88 22.2
with green/yellow ground wire 573-18-03 3 0.38 9.7 573-18-34 34 0.99 25.2
in the outer layer 573-18-04 4 0.42 10.6 573-18-41 41 1.08 27.4
Stranding: 573-18-05 5 0.45 11.4 573-18-50 50 1.13 28.8
cores twisted in layers 573-18-07 7 0.53 13.3
with very short lay lengths 573-18-12 12 0.63 16.0
fleece around cores, and inner 573-18-16 16 0.69 17.4
jacket gray plus common shield 573-18-18 18 0.72 18.1
Jacket: 16AWG (1,50 mm²) Stranding: VDE 0295, class 6 (84 x 0,15 mm)
Outer jacket black, flame retardant Part Numbers cond. O.D. inches O.D. mm Part Numbers cond. O.D. inches O.D. mm
and self-extinguishing, common 573-16-03 3 0.39 9.8 573-16-34 34 1.06 26.9
braided shield between jackets 573-16-04 4 0.44 11.0 573-16-42 42 1.18 30.0
Technical Data: 573-16-05 5 0.47 11.8 573-16-50 50 1.22 31.0
Rated voltage: 573-16-07 7 0.55 14.0
600 Volt 573-16-12 12 0.66 16.6
Test voltage: 573-16-16 16 0.70 17.6
4,000 volt 573-16-18 18 0.79 20.0
Bending radius: 573-16-25 25 0.92 23.3
fixed: 5 x diameter
flexible app.: 7.5 x diameter
Temperature range:
fixed: 23°F to 194°F
flex.: 23°F to 194°F


Sheet 10: G-C-14

CC-Schleppflex® PVC-C-573
Superflex shielded
Applications: 14AWG (2,50 mm²) Stranding: VDE 0295, class 6 (140 x 0,15 mm)
Power supply chains Part Numbers cond. O.D. inches O.D. mm Part Numbers cond. O.D. inches O.D. mm
Electical Equipments 573-14-03 3 0.46 11.5 573-14-12 12 0.79 20.0
UV, Oil and Cooling liquid resistant 573-14-04 4 0.50 12.7
Control devices 573-14-05 5 0.55 13.9
Whenever electrical interference 573-14-07 7 0.66 16.8
distorts signal transmission. 12AWG (4,00 mm²) Stranding: VDE 0295, class 6 (224 x 0,15 mm)
Specifications: Part Numbers cond. O.D. inches O.D. mm Part Numbers cond. O.D. inches O.D. mm
According to VDE 0245/0281 573-12-03 3 0.52 13.0 573-12-07 7 0.77 19.5
UL 2587/CSA AWM I A/B, II A.B FT1 573-12-04 4 0.59 14.8
Construction: 573-12-05 5 0.65 16.4
Conductors: 10AWG (6,00 mm²) Stranding: VDE 0295, class 6 (192 x 0,20 mm)
Fine bare copper strands acc. Part Numbers cond. O.D. inches O.D. mm Part Numbers cond. O.D. inches O.D. mm
to VDE 0295, class 6, with 573-10-04 4 0.67 16.9
PVC insulation 8AWG (10,00 mm²) Stranding: VDE 0295, class 6 (320 x 0,20 mm)
Color code: Part Numbers cond. O.D. inches O.D. mm Part Numbers cond. O.D. inches O.D. mm
black conductors with white 573-08-04 4 0.84 21.3
consec. numbers, cables with 6AWG (16,00 mm²) Stranding: VDE 0295, class 6 (512 x 0,20 mm)
three or more conductors Part Numbers cond. O.D. inches O.D. mm Part Numbers cond. O.D. inches O.D. mm
with green/yellow ground wire 573-06-04 4 1.02 25.9
in the outer layer
Stranding:
cores twisted in layers
with very short lay lengths
fleece around cores, and inner
jacket gray plus common shield
Jacket:
Outer jacket black, flame retardant
and self-extinguishing, common
braided shield between jackets
Technical Data:
Rated voltage:
600 Volt
Test voltage:
4,000 volt
Bending radius:
fixed: 5 x diameter
flexible app.: 7.5 x diameter
Temperature range:
fixed: 23°F to 194°F
flex.: 23°F to 194°F