RDE Connects

rde Connectors & Cables Inc.
5277 NW 108 Ave. Sunrise, FL 33351


Overview

G-D-01 G-D-02 G-D-03 G-D-05 G-D-10 G-D-11 G-D-12 G-D-15 G-D-20 G-D-21 G-D-22


Sheet 1: G-D-01

CC-Schleppflex® PUR-575
Superflex
Applications: 26AWG (0,14 mm²) Stranding: VDE 0295, class 6 (18 x 0,10 mm)
Power supply chains Part Numbers cond. O.D. inches O.D. mm Part Numbers cond. O.D. inches O.D. mm
Electical Equipments 575-0001-003 3 0.17 4.4 575-0001-014 14 0.29 7.3
Sensor technology 575-0001-004 4 0.18 4.6 575-0001-018 18 0.31 7.9
Control devices 575-0001-005 5 0.20 5.5 575-0001-025 25 0.37 9.3
Damp and wet areas 575-0001-007 7 0.24 6.0
Moving devices 575-0001-010 10 0.27 6.8
Abrasion resistant 24AWG (0,25 mm²) Stranding: VDE 0295, class 6 (32 x 0,10 mm)
Specifications: Part Numbers cond. O.D. inches O.D. mm Part Numbers cond. O.D. inches O.D. mm
According to VDE 575-0002-002 2 0.18 4.6 575-0002-014 14 0.33 8.3
0281, 0812, 0245 575-0002-003 3 0.19 4.8 575-0002-018 18 0.36 9.1
Construction: 575-0002-004 4 0.22 5.5 575-0002-025 25 0.44 11.1
Conductors: 575-0002-005 5 0.24 6.0
Fine bare copper strands acc. 575-0002-007 7 0.28 7.1
to VDE 0295, class 6, with 575-0002-010 10 0.32 8.0
PVC insulation 22AWG (0,34 mm²) Stranding: VDE 0295, class 6 (42 x 0,10 mm)
Color code: Part Numbers cond. O.D. inches O.D. mm Part Numbers cond. O.D. inches O.D. mm
acc. to DIN 47100 575-0003-002 2 0.21 5.2 575-0003-014 14 0.39 9.9
575-0003-003 3 0.22 5.5 575-0003-018 18 0.42 10.6
Stranding: 575-0003-004 4 0.26 6.6 575-0003-025 25 0.51 12.8
cores twisted in layers 575-0003-005 5 0.27 6.8
with very short lay lengths 575-0003-007 7 0.31 7.9
and fleece around cores 575-0003-010 10 0.36 9.2
Jacket:
PUR jacket gray
flame retardant and self-
extinguishing, resistant against
minaral oils, hydrolysis and
microbes
Technical Data:
Rated voltage:
250 Volt
Test voltage:
1,500 Volt
Bending radius:
fixed: 5 x diameter
flexible app.: 7.5 x diameter
Temperature range:
fixed: 23°F to 158°F
flex.: 23°F to 158°F


Sheet 2: G-D-02

CC-Schleppflex® PUR-575
Superflex
Applications: 20AWG (0,50 mm²) Stranding: VDE 0295, class 6 (28 x 0,15 mm)
Power supply chains Part Numbers cond. O.D. inches O.D. mm Part Numbers cond. O.D. inches O.D. mm
Electical Equipments 575-0005-003 3 0.26 6.6 575-0005-018 18 0.48 12.2
Harsh environment 575-0005-004 4 0.28 7.0 575-0005-025 25 0.62 15.8
Control devices 575-0005-005 5 0.29 7.4 575-0005-034 34 0.68 17.1
Damp and wet areas 575-0005-007 7 0.34 8.6
Moving devices 575-0005-012 12 0.40 10.1
Specifications: 18AWG (0,75 mm²) Stranding: VDE 0295, class 6 (42 x 0,15 mm)
According to VDE Part Numbers cond. O.D. inches O.D. mm Part Numbers cond. O.D. inches O.D. mm
0245, 0281 575-0007-003 3 0.27 6.8 575-0007-016 16 0.50 12.6
Construction: 575-0007-004 4 0.29 7.4 575-0007-018 18 0.53 13.5
Conductors: 575-0007-005 5 0.32 8.0 575-0007-025 25 0.66 16.7
Fine bare copper strands acc. 575-0007-007 7 0.38 9.5 575-0007-034 34 0.77 19.4
to VDE 0295, class 6, with 575-0007-012 12 0.45 11.3
PVC insulation 17AWG (1,00 mm²) Stranding: VDE 0295, class 6 (56 x 0,15 mm)
Color code: Part Numbers cond. O.D. inches O.D. mm Part Numbers cond. O.D. inches O.D. mm
black conductors with white 575-0010-003 3 0.29 7.2 575-0010-025 25 0.71 18.0
consec. numbers, cables with 575-0010-004 4 0.31 7.8 575-0010-034 34 0.78 19.8
three or more conductors 575-0010-005 5 0.34 8.5 575-0010-041 41 0.85 21.5
with green/yellow ground 575-0010-007 7 0.41 10.2 575-0010-050 50 0.91 23.1
wire in the outer layer 575-0010-012 12 0.48 12.2 575-0010-065 65 1.04 26.5
Stranding: 575-0010-016 16 0.55 13.8
cores twisted in layers 575-0010-018 18 0.58 14.7
with very short lay lengths 16AWG (1,50 mm²) Stranding: VDE 0295, class 6 (84 x 0,15 mm)
and fleece around cores Part Numbers cond. O.D. inches O.D. mm Part Numbers cond. O.D. inches O.D. mm
Jacket: 575-0015-003 3 0.32 8.0 575-0015-025 25 0.80 20.2
PUR jacket gray 575-0015-004 4 0.34 8.7 575-0015-034 34 0.86 21.9
flame retardant and self- 575-0015-005 5 0.39 9.7 575-0015-042 42 0.94 23.8
extinguishing, resistant against 575-0015-007 7 0.47 11.8 575-0015-050 50 1.02 26.0
mineral oils, hydrolysis, microbes 575-0015-012 12 0.54 13.7 575-0015-061 61 1.19 30.2
Technical Data: 575-0015-016 16 0.63 15.9
Rated voltage: 575-0015-018 18 0.65 16.5
300/500 Volt 14AWG (2,50 mm²) Stranding: VDE 0295, class 6 (140 x 0,15 mm)
Test voltage: Part Numbers cond. O.D. inches O.D. mm Part Numbers cond. O.D. inches O.D. mm
3,000 Volt 575-0025-003 3 0.38 9.6 575-0025-014 14 0.72 18.1
Bending radius: 575-0025-004 4 0.42 10.7 575-0025-018 18 0.85 21.5
fixed: 5 x diameter 575-0025-005 5 0.48 12.0 575-0025-025 25 1.05 26.6
flexible app.: 7.5 x diameter 575-0025-007 7 0.57 14.4
Temperature range: 575-0025-012 12 0.67 16.9
fixed: 23°F to 158°F
flex.: 23°F to 158°F


Sheet 3: G-D-03

CC-Schleppflex® PUR-575
Superflex
Applications: 12AWG (4,00 mm²) Stranding: VDE 0295, class 6 (224 x 0,15 mm)
Power supply chains Part Numbers cond. O.D. inches O.D. mm Part Numbers cond. O.D. inches O.D. mm
Electical Equipments 575-0040-003 3 0.45 11.4 575-0040-007 7 0.63 15.8
Harsh environment 575-0040-004 4 0.50 12.5
Control devices 575-0040-005 5 0.55 13.9
Damp and wet areas 10AWG (6,00 mm²) Stranding: VDE 0295, class 6 (192 x 0,20 mm)
Moving devices Part Numbers cond. O.D. inches O.D. mm Part Numbers cond. O.D. inches O.D. mm
Specifications: 575-0060-004 4 0.59 14.9
According to VDE 575-0060-005 5 0.65 16.4
0245, 0281 8AWG (10,00 mm²) Stranding: VDE 0295, class 6 (320 x 0,20 mm)
Construction: Part Numbers cond. O.D. inches O.D. mm Part Numbers cond. O.D. inches O.D. mm
Conductors: 575-0100-004 4 0.73 18.5
Fine bare copper strands acc. 575-0100-005 5 0.81 20.4
to VDE 0295, class 6, with 6AWG (16,00 mm²) Stranding: VDE 0295, class 6 (512 x 0,20 mm)
PVC insulation Part Numbers cond. O.D. inches O.D. mm Part Numbers cond. O.D. inches O.D. mm
Color code: 575-0160-004 4 0.86 21.8
black conductors with white 575-0160-005 5 0.95 24.0
consec. numbers, cables with
three or more conductors
with green/yellow ground
wire in the outer layer
Stranding:
cores twisted in layers
with very short lay lengths
and fleece around cores
Jacket:
PUR jacket gray
flame retardant and self-
extinguishing, resistant against
mineral oils, hydrolysis, microbes
Technical Data:
Rated voltage:
300/500 Volt
Test voltage:
3,000 Volt
Bending radius:
fixed: 5 x diameter
flexible app.: 7.5 x diameter
Temperature range:
fixed: 23°F to 158°F
flex.: 23°F to 158°F


Sheet 4: G-D-05

CC-Schleppflex® PUR-575-UL
Superflex
Applications: 20AWG (0,50 mm²) Stranding: VDE 0295, class 6 (28 x 0,15 mm)
Power supply chains Part Numbers cond. O.D. inches O.D. mm Part Numbers cond. O.D. inches O.D. mm
Electical Equipments 575-20-03 3 0.28 7.1 575-20-18 18 0.54 13.6
Harsh environment 575-20-04 4 0.32 8.1 575-20-25 25 0.65 16.3
Control devices 575-20-05 5 0.33 8.4 575-20-34 34 0.75 19.0
Moving devices 575-20-07 7 0.39 9.7
Specifications: 575-20-12 12 0.46 11.6
According to VDE 0245/0281 19AWG (0,75 mm²) Stranding: VDE 0295, class 6 (42 x 0,15 mm)
UL style 10012/20234 Part Numbers cond. O.D. inches O.D. mm Part Numbers cond. O.D. inches O.D. mm
CSA AWM 1 A/B, II A/B FT 1 575-19-03 3 0.28 6.9 575-19-16 16 0.54 13.6
Construction: 575-19-04 4 0.30 7.5 575-19-18 18 0.56 14.1
Conductors: 575-19-05 5 0.33 8.2 575-19-25 25 0.68 17.3
Fine bare copper strands acc. 575-19-07 7 0.40 10.1 575-19-34 34 0.78 19.7
to VDE 0295, class 6, with 575-19-12 12 0.51 12.9
PVC insulation 18AWG (1.00 mm²) Stranding: VDE 0295, class 6 (56 x 0,15 mm)
Color code: Part Numbers cond. O.D. inches O.D. mm Part Numbers cond. O.D. inches O.D. mm
black conductors with white 575-18-03 3 0.28 7.1 575-18-16 16 0.57 14.4
consec. numbers, cables with 575-18-04 4 0.30 7.7 575-18-18 18 0.58 14.6
three or more conductors 575-18-05 5 0.34 8.5 575-18-25 25 0.71 18.0
with green/yellow ground 575-18-07 7 0.41 10.4 575-18-34 34 0.81 20.4
wire in the outer layer 575-18-12 12 0.49 12.5 575-18-41 41 0.99 25.0
Stranding: 16AWG (1.50 mm²) Stranding: VDE 0295, class 6 (84 x 0,15 mm)
cores twisted in layers Part Numbers cond. O.D. inches O.D. mm Part Numbers cond. O.D. inches O.D. mm
with very short lay lengths 575-16-03 3 0.34 8.5 575-16-18 18 0.67 17.0
and fleece around cores 575-16-04 4 0.37 9.3 575-16-25 25 0.82 20.8
Jacket: 575-16-05 5 0.40 10.1 575-16-34 34 0.89 22.6
PUR jacket gray 575-16-07 7 0.47 11.9 575-16-50 50 1.12 28.4
flame retardant and self- 575-16-12 12 0.56 14.3 557-16-61 61 1.18 30.0
extinguishing, resistant against 575-16-16 16 0.64 16.2
mineral oils, hydrolysis, microbes 14AWG (2.50 mm²) Stranding: VDE 0295, class 6 (140 x 0,15 mm)
Technical Data: Part Numbers cond. O.D. inches O.D. mm Part Numbers cond. O.D. inches O.D. mm
Rated voltage: 575-14-03 3 0.41 10.2 575-14-07 7 0.57 14.5
600 Volt 575-14-04 4 0.44 11.1 575-14-12 12 0.71 18.0
Test voltage: 575-14-05 5 0.48 12.1
4,000 Volt 12AWG (4.00 mm²) Stranding: VDE 0295, class 6 (224 x 0,15 mm)
Bending radius: Part Numbers cond. O.D. inches O.D. mm Part Numbers cond. O.D. inches O.D. mm
fixed: 5 x diameter 575-12-04 4 0.53 13.4 575-12-07 7 0.73 18.5
flexible app.: 7.5 x diameter 575-12-05 5 0.59 14.8
Temperature range: 10AWG (6.00 mm²) Stranding: VDE 0295, class 6 (192 x 0,20 mm)
fixed: 23°F to 176°F Part Numbers cond. O.D. inches O.D. mm Part Numbers cond. O.D. inches O.D. mm
flex.: 23°F to 176°F 575-10-04 4 0.60 15.1


Sheet 5: G-D-10

CC-Schleppflex® PUR-C-576
Superflex shielded
Applications: 26AWG (0,14 mm²) Stranding: VDE 0295, class 6 (18 x 0,10 mm)
Power supply chains Part Numbers cond. O.D. inches O.D. mm Part Numbers cond. O.D. inches O.D. mm
Electical Equipments 576-0001-002 2 0.17 4.3 576-0001-012 12 0.30 7.5
Sensor technology 576-0001-003 3 0.18 4.5 576-0001-014 14 0.30 7.6
Control devices 576-0001-004 4 0.19 4.8 576-0001-018 18 0.33 8.4
Damp and wet areas 576-0001-005 5 0.20 5.1 576-0001-025 25 0.39 9.9
Whenever elecrical interference 576-0001-007 7 0.25 6.4
distorts signal transmission. 576-0001-010 10 0.29 7.3
Specifications: 24AWG (0,25 mm²) Stranding: VDE 0295, class 6 (32 x 0,10 mm)
According to VDE Part Numbers cond. O.D. inches O.D. mm Part Numbers cond. O.D. inches O.D. mm
0281, 0812, 0245 576-0002-002 2 0.19 4.7 576-0002-012 12 0.34 8.6
Construction: 576-0002-003 3 0.20 4.9 576-0002-014 14 0.35 8.7
Conductors: 576-0002-004 4 0.23 5.7 576-0002-018 18 0.38 9.6
Fine bare copper strands acc. 576-0002-005 5 0.25 6.3 576-0002-025 25 0.45 11.3
to VDE 0295, class 6, with 576-0002-007 7 0.28 7.1
PVC insulation 576-0002-010 10 0.33 8.3
Color code: 22AWG (0,34 mm²) Stranding: VDE 0295, class 6 (42 x 0,10 mm)
acc. to DIN 47100 Part Numbers cond. O.D. inches O.D. mm Part Numbers cond. O.D. inches O.D. mm
576-0003-002 2 0.23 5.7 576-0003-012 12 0.40 10.1
Stranding: 576-0003-003 3 0.25 6.2 576-0003-014 14 0.40 10.2
cores twisted in layers 576-0003-004 4 0.26 6.6 576-0003-018 18 0.45 11.3
with very short lay lengths 576-0003-005 5 0.28 7.1 576-0003-025 25 0.54 13.6
and fleece around cores 576-0003-007 7 0.33 8.3
plus common braided shield 576-0003-010 10 0.39 9.8
Jacket:
PUR jacket gray
flame retardant and self-
extinguishing, resistant against
minaral oils, hydrolysis and
microbes
Technical Data:
Rated voltage:
250 Volt
Test voltage:
1,500 Volt
Bending radius:
fixed: 5 x diameter
flexible app.: 7.5 x diameter
Temperature range:
fixed: 23°F to 158°F
flex.: 23°F to 158°F


Sheet 6: G-D-11

CC-Schleppflex® PUR-C-576
Superflex shielded
Applications: 20AWG (0.50 mm²) Stranding: VDE 0295, class 6 (28 x 0.15 mm)
Power supply chains Part Numbers cond. O.D. inches O.D. mm Part Numbers cond. O.D. inches O.D. mm
Sensor technology 576-0005-003 3 0.31 7.8 576-0005-025 25 0.64 16.1
Control devices 576-0005-004 4 0.31 7.9
Damp and wet areas 576-0005-005 5 0.33 8.4
Whenever elecrical interference 576-0005-007 7 0.39 9.8
distorts signal transmission. 576-0005-012 12 0.45 11.3
Specifications: 576-0005-018 18 0.53 13.4
According to VDE 0281, 0245 18AWG (0.75 mm²) Stranding: VDE 0295, class 6 (42 x 0.15 mm)
Construction: Part Numbers cond. O.D. inches O.D. mm Part Numbers cond. O.D. inches O.D. mm
Conductors: 576-0007-003 3 0.31 7.8 576-0007-018 18 0.59 14.9
Fine bare copper strands acc. 576-0007-004 4 0.33 8.4 576-0007-025 25 0.71 18.0
to VDE 0295, class 6, with 576-0007-005 5 0.36 9.0 576-0007-034 34 0.87 22.0
PVC insulation 576-0007-007 7 0.42 10.7
Color code: 576-0007-012 12 0.49 12.4
black cond. with white consec. 576-0007-014 14 0.55 14.0
numbers, cables with three or 17AWG (1.00 mm²) Stranding: VDE 0295, class 6 (56 x 0.15 mm)
more cond. with yellow/green Part Numbers cond. O.D. inches O.D. mm Part Numbers cond. O.D. inches O.D. mm
ground wire in the outer layer 576-0010-003 3 0.33 8.2 576-0010-025 25 0.77 19.5
Stranding: 576-0010-004 4 0.35 8.9 576-0010-034 34 0.93 23.5
cores twisted in layers with 576-0010-005 5 0.39 9.8 576-0010-041 41 1.00 25.4
very short lay lengths and fleece 576-0010-007 7 0.45 11.4 576-0010-050 50 1.06 27.1
around cores, plus common 576-0010-012 12 0.53 13.4 576-0010-065 65 1.24 31.4
shield and inner jacket PVC 576-0010-016 16 0.60 15.2
Jacket: 576-0010-018 18 0.64 16.1
outer PUR jacket, gray 16AWG (1.50 mm²) Stranding: VDE 0295, class 6 (84 x 0.15 mm)
flame retardant and self- Part Numbers cond. O.D. inches O.D. mm Part Numbers cond. O.D. inches O.D. mm
extinguishing, resistant against 576-0015-003 3 0.36 9.0 576-0015-025 25 0.86 21.9
minaral oils, hydrolysis and 576-0015-004 4 0.39 9.9 576-0015-034 34 1.08 27.5
microbes 576-0015-005 5 0.43 10.9 576-0015-042 42 1.17 29.8
Technical Data: 576-0015-007 7 0.50 12.7 576-0015-050 50 1.27 32.3
Rated voltage: 576-0015-012 12 0.60 15.1
300/500 Volt 576-0015-016 16 0.66 16.8
Test voltage: 576-0015-018 18 0.70 17.8
3,000 Volt
Bending radius:
fixed: 5 x diameter
flexible app.: 7.5 x diameter
Temperature range:
fixed: 23°F to 158°F
flex.: 23°F to 158°F


Sheet 7: G-D-12

CC-Schleppflex® PUR-C-576
Superflex shielded
Applications: 14AWG (2.50 mm²) Stranding: VDE 0295, class 6 (140 x 0.15 mm)
Power supply chains Part Numbers cond. O.D. inches O.D. mm Part Numbers cond. O.D. inches O.D. mm
Sensor technology 576-0025-003 3 0.43 10.8 576-0025-007 7 0.63 15.8
Control devices 576-0025-004 4 0.47 11.8 576-0025-012 12 0.72 18.2
Damp and wet areas 576-0025-005 5 0.52 13.2
Whenever elecrical interference 12AWG (4.00 mm²) Stranding: VDE 0295, class 6 (224 x 0.15 mm)
distorts signal transmission. Part Numbers cond. O.D. inches O.D. mm Part Numbers cond. O.D. inches O.D. mm
Specifications: 576-0040-003 3 0.49 12.4
According to VDE 0281, 0245 576-0040-004 4 0.54 13.7
Construction: 576-0040-005 5 0.61 15.3
Conductors: 10AWG (6.00 mm²) Stranding: VDE 0295, class 6 (192 x 0.20 mm)
Fine bare copper strands acc. Part Numbers cond. O.D. inches O.D. mm Part Numbers cond. O.D. inches O.D. mm
to VDE 0295, class 6, with 576-0060-004 4 0.64 16.1
PVC insulation 576-0060-005 5 0.68 17.1
Color code: 8AWG (10.00 mm²) Stranding: VDE 0295, class 6 (320 x 0.20 mm)
black cond. with white consec. Part Numbers cond. O.D. inches O.D. mm Part Numbers cond. O.D. inches O.D. mm
numbers, cables with three or 576-0100-004 4 0.80 20.2
more cond. with yellow/green 576-0100-005 5 0.88 22.2
ground wire in the outer layer 6AWG (16.00 mm²) Stranding: VDE 0295, class 6 (512 x 0.20 mm)
Stranding: Part Numbers cond. O.D. inches O.D. mm Part Numbers cond. O.D. inches O.D. mm
cores twisted in layers with 576-0160-004 4 0.92 23.2
very short lay lengths and fleece 576-0160-005 5 1.03 26.1
around cores, plus common
shield and inner jacket PVC
Jacket:
outer PUR jacket, gray
flame retardant and self-
extinguishing, resistant against
minaral oils, hydrolysis and
microbes
Technical Data:
Rated voltage:
300/500 Volt
Test voltage:
3,000 Volt
Bending radius:
fixed: 5 x diameter
flexible app.: 7.5 x diameter
Temperature range:
fixed: 23°F to 158°F
flex.: 23°F to 158°F


Sheet 8: G-D-15

CC-Schleppflex® PUR-C-576-UL
Superflex shielded
Applications: 20AWG (0.50 mm²) Stranding: VDE 0295, class 6 (28 x 0.15 mm)
Power supply chains Part Numbers cond. O.D. inches O.D. mm Part Numbers cond. O.D. inches O.D. mm
Control devices 576-20-03 3 0.36 9.1 576-20-12 12 0.55 14.0
Whenever elecrical interference 576-20-04 4 0.39 9.8 576-20-18 18 0.64 16.2
distorts signal transmission. 576-20-05 5 0.41 10.4 576-20-25 25 0.76 19.3
Specifications: 576-20-07 7 0.46 11.6 576-20-34 34 0.85 21.5
According to VDE 0281, 0245 19AWG (0.75 mm²) Stranding: VDE 0295, class 6 (42 x 0.15 mm)
UL style 10012/20234 Part Numbers cond. O.D. inches O.D. mm Part Numbers cond. O.D. inches O.D. mm
CSA AWM I A/B, II A/B FT 1 576-19-03 3 0.37 9.2 576-19-16 16 0.63 16.0
Construction: 576-19-04 4 0.41 10.2 576-19-18 18 0.72 18.2
Conductors: 576-19-05 5 0.43 10.9 576-19-25 25 0.83 21.0
Fine bare copper strands acc. 576-19-07 7 0.50 12.7 576-19-34 34 0.94 23.8
to VDE 0295, class 6, with 576-19-12 12 0.59 14.8
PVC insulation 18AWG (1.00 mm²) Stranding: VDE 0295, class 6 (56 x 0.15 mm)
Color code: Part Numbers cond. O.D. inches O.D. mm Part Numbers cond. O.D. inches O.D. mm
black cond. with white consec. 576-18-03 3 0.37 9.4 576-18-16 16 0.68 17.2
numbers, cables with three or 576-18-04 4 0.41 10.4 576-18-18 18 0.75 18.9
more cond. with yellow/green 576-18-05 5 0.44 11.2 576-18-25 25 0.87 22.0
ground wire in the outer layer 576-18-07 7 0.52 13.2 576-18-34 34 0.97 24.5
Stranding: 576-18-12 12 0.62 15.6 576-18-41 41 1.05 26.7
cores twisted in layers with 16AWG (1.50 mm²) Stranding: VDE 0295, class 6 (84 x 0.15 mm)
very short lay lengths and fleece Part Numbers cond. O.D. inches O.D. mm Part Numbers cond. O.D. inches O.D. mm
around cores, plus common 576-16-03 3 0.42 10.6 756-16-16 16 0.74 18.8
shield and inner jacket PVC 576-16-04 4 0.45 11.4 576-16-18 18 0.77 19.6
Jacket: 576-16-05 5 0.49 12.3 576-16-25 25 0.93 23.6
outer PUR jacket, gray 576-16-07 7 0.56 14.1 576-16-34 34 1.06 27.0
flame retardant and self- 576-16-12 12 0.68 17.2 576-16-50 50 1.26 32.0
extinguishing, resistant against 14AWG (2.50 mm²) Stranding: VDE 0295, class 6 (140 x 0.15 mm)
minaral oils, hydrolysis and Part Numbers cond. O.D. inches O.D. mm Part Numbers cond. O.D. inches O.D. mm
microbes 576-14-03 3 0.50 12.6 576-14-07 7 0.67 16.9
Technical Data: 576-14-04 4 0.53 13.5 576-14-12 12 0.84 21.2
Rated voltage: 576-14-05 5 0.59 15.0 576-14-18 18 0.93 23.6
600 Volt 12AWG (4.00 mm²) Stranding: VDE 0295, class 6 (224 x 0.15 mm)
Test voltage: Part Numbers cond. O.D. inches O.D. mm Part Numbers cond. O.D. inches O.D. mm
4,000 Volt 576-12-04 4 0.63 16.0 576-12-07 7 0.78 19.8
Bending radius: 10AWG (6.00 mm²) Stranding: VDE 0295, class 6 (192 x 0.20 mm)
fixed: 5 x diameter Part Numbers cond. O.D. inches O.D. mm Part Numbers cond. O.D. inches O.D. mm
flexible app.: 7.5 x diameter 576-10-04 4 0.70 17.7 576-10-07 7 0.93 23.6
Temperature range: 8AWG (10.00 mm²) Stranding: VDE 0295, class 6 (320 x 0.20 mm)
fixed: 23°F to 176°F Part Numbers cond. O.D. inches O.D. mm Part Numbers cond. O.D. inches O.D. mm
flex.: 23°F to 176°F 576-08-04 4 0.71 18.0


Sheet 9: G-D-20

CC-Schleppflex® PUR-572
Superflex halogen-free
Applications: 26AWG (0,14 mm²) Stranding: VDE 0295, class 6 (18 x 0,10 mm)
Power supply chains Part Numbers cond. O.D. inches O.D. mm Part Numbers cond. O.D. inches O.D. mm
Electical Equipments 572-0001-002 2 0.17 4.2 572-0001-012 12 0.24 6.0
Sensor technology 572-0001-003 3 0.18 4.4 572-0001-014 14 0.26 6.6
Control devices 572-0001-004 4 0.18 4.6 572-0001-018 18 0.28 6.9
Damp and wet areas 572-0001-005 5 0.20 4.9 572-0001-025 25 0.33 8.2
Moving devices 572-0001-007 7 0.23 5.7
Abrasion resistant 572-0001-010 10 0.24 5.9
Specifications: 24AWG (0.25 mm²) Stranding: VDE 0295, class 6 (32 x 0.10 mm)
According to VDE Part Numbers cond. O.D. inches O.D. mm Part Numbers cond. O.D. inches O.D. mm
0281, 0812, 0245 572-0002-002 2 0.16 4.1 572-0002-012 12 0.32 8.1
Construction: 572-0002-003 3 0.18 4.5 572-0002-014 14 0.33 8.3
Conductors: 572-0002-004 4 0.19 4.8 572-0002-018 18 0.35 8.9
Fine bare copper strands acc. 572-0002-005 5 0.20 5.0 572-0002-025 25 0.44 11.0
to VDE 0295, class 6, with 572-0002-007 7 0.24 6.0
TPE insulation 572-0002-010 10 0.29 7.3
Color code: 22AWG (0.34 mm²) Stranding: VDE 0295, class 6 (42 x 0.10 mm)
acc. to DIN 47100 Part Numbers cond. O.D. inches O.D. mm Part Numbers cond. O.D. inches O.D. mm
572-0003-002 2 0.20 4.9 572-0003-012 12 0.35 8.8
Stranding: 572-0003-003 3 0.20 5.1 572-0003-014 14 0.37 9.3
cores twisted in layers 572-0003-004 4 0.23 5.7 572-0003-018 18 0.41 10.2
with very short lay lengths 572-0003-005 5 0.25 6.3 572-0003-025 25 0.49 12.3
and fleece around cores 572-0003-007 7 0.29 7.2
bandage over each layer 572-0003-010 10 0.34 8.6
Jacket:
PUR jacket gray
flame retardant and self-
extinguishing, resistant against
minaral oils, hydrolysis and
microbes
Technical Data:
Rated voltage:
250 Volt
Test voltage:
1,500 Volt
Bending radius:
fixed: 5 x diameter
flexible app.: 7.5 x diameter
Temperature range:
fixed: - 22°F to 176°F
flex.: - 22°F to 176°F


Sheet 10: G-D-21

CC-Schleppflex® PUR-572
Superflex halogen-free
Applications: 20AWG (0,50 mm²) Stranding: VDE 0295, class 6 (28 x 0,15 mm)
Power supply chains Part Numbers cond. O.D. inches O.D. mm Part Numbers cond. O.D. inches O.D. mm
Electical Equipments 572-0005-002 2 0.20 5.1 572-0005-025 25 0.50 12.6
Harsh environment 572-0005-003 3 0.22 5.4 572-0005-027 27 0.53 13.3
Control devices 572-0005-004 4 0.23 5.8 572-0005-030 30 0.54 13.8
Damp and wet areas 572-0005-005 5 0.25 6.2 572-0005-034 34 0.56 14.1
Moving devices 572-0005-007 7 0.29 7.4 572-0005-036 36 0.57 14.3
Specifications: 572-0005-012 12 0.35 8.8 572-0005-041 41 0.59 15.0
According to VDE 572-0005-014 14 0.39 9.7 572-0005-050 50 0.66 16.8
0245, 0281 572-0005-018 18 0.42 10.6
Construction: 572-0005-020 20 0.44 11.2
Conductors: 18AWG (0.75 mm²) Stranding: VDE 0295, class 6 (42 x 0.15 mm)
Fine bare copper strands acc. Part Numbers cond. O.D. inches O.D. mm Part Numbers cond. O.D. inches O.D. mm
to VDE 0295, class 6, with 572-0007-002 2 0.22 5.5 572-0007-030 30 0.60 15.1
TPE insulation 572-0007-003 3 0.23 5.8 572-0007-034 34 0.61 15.4
Color code: 572-0007-004 4 0.25 6.3 572-0007-036 36 0.62 15.7
black conductors with white 572-0007-005 5 0.28 6.9 572-0007-041 41 0.68 17.1
consec. numbers, cables with 572-0007-007 7 0.32 8.1 572-0007-050 50 0.74 18.6
three or more conductors 572-0007-012 12 0.40 10.1
with green/yellow ground 572-0007-014 14 0.42 10.6
wire in the outer layer 572-0007-018 18 0.46 11.6
Stranding: 572-0007-020 20 0.48 12.2
cores twisted in layers with very 572-0007-025 25 0.55 14.0
short lay lengths and fleece around 17AWG (1.00 mm²) Stranding: VDE 0295, class 6 (56 x 0.15 mm)
cores, bandage over each layer Part Numbers cond. O.D. inches O.D. mm Part Numbers cond. O.D. inches O.D. mm
Jacket: 572-0010-002 2 0.24 6.1 572-0010-027 27 0.64 16.1
PUR jacket gray 572-0010-003 3 0.25 6.3 572-0010-030 30 0.65 16.3
flame retardant and self- 572-0010-004 4 0.28 7.0 572-0010-034 34 0.66 16.8
extinguishing, resistant against 572-0010-005 5 0.30 7.5 572-0010-036 36 0.68 17.3
mineral oils, hydrolysis, microbes 572-0010-007 7 0.35 8.7 572-0010-041 41 0.73 18.4
Technical Data: 572-0010-012 12 0.42 10.5 572-0010-050 50 0.81 20.4
Rated voltage: 572-0010-014 14 0.46 11.5 572-0010-065 65 0.90 22.8
300/500 Volt 572-0010-018 18 0.50 12.7
Test voltage: 572-0010-020 20 0.54 13.6
3,000 Volt 572-0010-025 25 0.60 15.2
Bending radius:
fixed: 5 x diameter
flexible app.: 5 x diameter
Temperature range:
fixed: -22°F to 176°F
flex.: -22°F to 176°F


Sheet 11: G-D-22

CC-Schleppflex® PUR-572
Superflex halogen-free
Applications: 16AWG (1,50 mm²) Stranding: VDE 0295, class 6 (84 x 0.15 mm)
Power supply chains Part Numbers cond. O.D. inches O.D. mm Part Numbers cond. O.D. inches O.D. mm
Electical Equipments 572-0015-002 2 0.26 6.5 572-0015-027 27 0.70 17.6
Harsh environment 572-0015-003 3 0.28 7.1 572-0015-030 30 0.72 18.1
Control devices 572-0015-004 4 0.31 7.7 572-0015-034 34 0.76 19.2
Damp and wet areas 572-0015-005 5 0.33 8.3 572-0015-036 36 0.77 19.4
Moving devices 572-0015-007 7 0.40 10.1 572-0015-042 42 0.84 21.2
Specifications: 572-0015-012 12 0.48 12.2 572-0015-050 50 1.07 27.2
According to VDE 572-0015-014 14 0.52 13.1 572-0015-061 61 1.18 30.0
0245, 0281 572-0015-018 18 0.56 14.3 572-0015-065 65 1.25 31.7
Construction: 572-0015-020 20 0.60 15.3
Conductors: 572-0015-025 25 0.68 17.3
Fine bare copper strands acc. 14AWG (2.50 mm²) Stranding: VDE 0295, class 6 (140 x 0.15 mm)
to VDE 0295, class 6, with Part Numbers cond. O.D. inches O.D. mm Part Numbers cond. O.D. inches O.D. mm
TPE insulation 572-0025-003 3 0.33 8.4 572-0025-014 14 0.61 15.5
Color code: 572-0025-004 4 0.35 8.9 572-0025-018 18 0.68 17.2
black conductors with white 572-0025-005 5 0.40 10.1 572-0025-025 25 0.83 21.1
consec. numbers, cables with 572-0025-007 7 0.46 11.7
three or more conductors 572-0025-012 12 0.56 14.2
with green/yellow ground 12AWG (4.00 mm²) Stranding: VDE 0295, class 6 (224 x 0.15 mm)
wire in the outer layer Part Numbers cond. O.D. inches O.D. mm Part Numbers cond. O.D. inches O.D. mm
Stranding: 572-0040-003 3 0.41 10.2 572-0040-005 5 0.48 12.1
cores twisted in layers with very 572-0040-004 4 0.44 11.1 572-0040-007 7 0.57 14.4
short lay lengths and fleece around 10AWG (6.00 mm²) Stranding: VDE 0295, class 6 (192 x 0.20 mm)
cores, bandage over each layer Part Numbers cond. O.D. inches O.D. mm Part Numbers cond. O.D. inches O.D. mm
Jacket: 572-0060-003 3 0.46 11.5 572-0060-005 5 0.55 13.9
PUR jacket gray 572-0060-004 4 0.49 12.5 572-0060-007 7 0.66 16.6
flame retardant and self- 8AWG (10.00 mm²) Stranding: VDE 0295, class 6 (320 x 0.20 mm)
extinguishing, resistant against Part Numbers cond. O.D. inches O.D. mm Part Numbers cond. O.D. inches O.D. mm
mineral oils, hydrolysis, microbes 572-0100-003 3 0.57 14.5 572-0100-005 5 0.71 17.9
Technical Data: 572-0100-004 4 0.64 16.1
Rated voltage: 6AWG (16.00 mm²) Stranding: VDE 0295, class 6 (512 x 0.20 mm)
300/500 Volt Part Numbers cond. O.D. inches O.D. mm Part Numbers cond. O.D. inches O.D. mm
Test voltage: 572-0160-004 4 0.75 18.9
3,000 Volt 572-0160-005 5 0.82 20.8
Bending radius:
fixed: 5 x diameter
flexible app.: 5 x diameter
Temperature range:
fixed: -22°F to 176°F