RDE Connects

rde Connectors & Cables Inc.
5277 NW 108 Ave. Sunrise, FL 33351


Overview

G-F-01 G-F-03 G-F-05 G-F-07 G-F-09 G-F-15 G-F-16 G-F-17


Sheet 1: G-F-01

CC-Servo Motor-supply PVC-586-UL
with filler if necessary Highflex
Applications: 16AWG (1.50 mm²) Stranding: VDE 0295, class 5 (30 x 0,25 mm)
Servo Motors Part Numbers cond. O.D. inches O.D. mm Part Numbers cond. O.D. inches O.D. mm
DNC Motors 586-160-408 4 0.39 9.9
UV resistant 14AWG (2.50 mm²) Stranding: VDE 0295, class 5 (50 x 0,25 mm)
Oil resistant Part Numbers cond. O.D. inches O.D. mm Part Numbers cond. O.D. inches O.D. mm
Coolant resistant 586-140-408 4 0.44 11.1
Specifications: 12AWG (4.00 mm²) Stranding: VDE 0295, class 5 (56 x 0,30 mm)
According to VDE 0281 Part Numbers cond. O.D. inches O.D. mm Part Numbers cond. O.D. inches O.D. mm
cUL style 20886 586-120-408 4 0.55 13.8
10AWG (6.00 mm²) Stranding: VDE 0295, class 5 (84 x 0,30 mm)
Construction: Part Numbers cond. O.D. inches O.D. mm Part Numbers cond. O.D. inches O.D. mm
Conductors: 586-100-408 4 0.62 15.6
Bare copper strands acc. 8AWG (10.00 mm²) Stranding: VDE 0295, class 5 (80 x 0.40 mm)
to VDE 0295, class 5, with Part Numbers cond. O.D. inches O.D. mm Part Numbers cond. O.D. inches O.D. mm
PVC insulation 586-080-408 4 0.73 18.4
Color code: 6AWG (16.00 mm²) Stranding: VDE 0295, class 5 (128 x 0.40 mm)
black conductors with white Part Numbers cond. O.D. inches O.D. mm Part Numbers cond. O.D. inches O.D. mm
numbers 1, 2, 3 plus one ground 586-060-408 4 0.86 21.7
wire green/yellow 4AWG (25.00 mm²) Stranding: VDE 0295, class 5 (200 x 0.40 mm)
Part Numbers cond. O.D. inches O.D. mm Part Numbers cond. O.D. inches O.D. mm
Stranding: 586-040-408 4 1.06 26.9
cores twisted in layers 2AWG (35.00 mm²) Stranding: VDE 0295, class 5 (280 x 0.40 mm)
Part Numbers cond. O.D. inches O.D. mm Part Numbers cond. O.D. inches O.D. mm
Jacket: 586-020-408 4 1.18 30.0
PVC jacket black 1AWG (50.00 mm²) Stranding: VDE 0295, class 5 (400 x 0.40 mm)
flame retardant and self- Part Numbers cond. O.D. inches O.D. mm Part Numbers cond. O.D. inches O.D. mm
extinguishing 586-010-408 4 1.36 34.5
Technical Data:
Rated voltage:
1,000 Volt
Test voltage:
4,000 volt
Bending radius:
fixed: 5 x diameter
flexible app.: 7.5 x diameter
Temperature range:
fixed: -22°F to 176°F
flex.: 23°F to 158°F


Sheet 2: G-F-03

CC-Servo Motor-supply PVC-C-585-UL
Highflex shielded
Applications: 16AWG (1.50 mm²) Stranding: VDE 0295, class 5 (30 x 0,25 mm)
Servo Motors Part Numbers cond. O.D. inches O.D. mm Part Numbers cond. O.D. inches O.D. mm
DNC Motors 585-160-408 4 0.52 13.1
Oil and coolant resistant 14AWG (2.50 mm²) Stranding: VDE 0295, class 5 (50 x 0,25 mm)
Whenever electrical interference Part Numbers cond. O.D. inches O.D. mm Part Numbers cond. O.D. inches O.D. mm
distorts signal transmission. 585-140-408 4 0.59 14.8
Specifications: 12AWG (4.00 mm²) Stranding: VDE 0295, class 5 (56 x 0,30 mm)
According to VDE 0281 Part Numbers cond. O.D. inches O.D. mm Part Numbers cond. O.D. inches O.D. mm
cUL style 20886 585-120-408 4 0.69 17.4
10AWG (6.00 mm²) Stranding: VDE 0295, class 5 (84 x 0,30 mm)
Construction: Part Numbers cond. O.D. inches O.D. mm Part Numbers cond. O.D. inches O.D. mm
Conductors: 585-100-408 4 0.78 19.8
Bare copper strands acc. 8AWG (10.00 mm²) Stranding: VDE 0295, class 5 (80 x 0.40 mm)
to VDE 0295, class 5, with Part Numbers cond. O.D. inches O.D. mm Part Numbers cond. O.D. inches O.D. mm
PVC insulation 585-080-408 4 0.99 25.1
Color code: 6AWG (16.00 mm²) Stranding: VDE 0295, class 5 (128 x 0.40 mm)
black conductors with white Part Numbers cond. O.D. inches O.D. mm Part Numbers cond. O.D. inches O.D. mm
numbers 1, 2, 3 plus one ground 585-060-408 4 1.07 27.3
wire green/yellow 4AWG (25.00 mm²) Stranding: VDE 0295, class 5 (200 x 0.40 mm)
Part Numbers cond. O.D. inches O.D. mm Part Numbers cond. O.D. inches O.D. mm
Stranding: 585-040-408 4 1.34 34.0
cores twisted in layers with inner 2AWG (35.00 mm²) Stranding: VDE 0295, class 5 (280 x 0.40 mm)
PVC jacket and common shield Part Numbers cond. O.D. inches O.D. mm Part Numbers cond. O.D. inches O.D. mm
Jacket: 585-020-408 4 1.46 37.2
Outer jacket orange PVC 1AWG (50.00 mm²) Stranding: VDE 0295, class 5 (400 x 0.40 mm)
flame retardant and self- Part Numbers cond. O.D. inches O.D. mm Part Numbers cond. O.D. inches O.D. mm
extinguishing 585-010-408 4 1.71 43.4
Technical Data:
Rated voltage:
1,000 Volt
Test voltage:
4,000 volt
Bending radius:
fixed: 7 x diameter
flexible app.: 10 x diameter
Temperature range:
fixed: -22°F to 176°F
flex.: 23°F to 158°F


Sheet 3: G-F-05

CC-Servo Motor-supply PUR-580-UL
Superflex halogen-free
Applications: 16AWG (1.50 mm²) Stranding: VDE 0295, class 6 (84 x 0.15 mm)
Servo Motors Part Numbers cond. O.D. inches O.D. mm Part Numbers cond. O.D. inches O.D. mm
Power supply chains 580-160-400 4 0.34 8.5
handling equipments 14AWG (2.50 mm²) Stranding: VDE 0295, class 6 (140 x 0.15 mm)
Oil and coolant resistant Part Numbers cond. O.D. inches O.D. mm Part Numbers cond. O.D. inches O.D. mm
high mechanical stress 580-140-400 4 0.41 10.2
Specifications: 12AWG (4.00 mm²) Stranding: VDE 0295, class 6 (224 x 0.15 mm)
According to VDE 0245/0281 Part Numbers cond. O.D. inches O.D. mm Part Numbers cond. O.D. inches O.D. mm
UL style 10264/20235 580-120-400 4 0.46 11.6
CSA style AWM I A/B, II A/B FT 1 10AWG (6.00 mm²) Stranding: VDE 0295, class 6 (192 x 0.20 mm)
Construction: Part Numbers cond. O.D. inches O.D. mm Part Numbers cond. O.D. inches O.D. mm
Conductors: 580-100-400 4 0.52 13.2
Fine bare copper strands acc. 8AWG (10.00 mm²) Stranding: VDE 0295, class 6 (320 x 0.20 mm)
to VDE 0295, class 6, with Part Numbers cond. O.D. inches O.D. mm Part Numbers cond. O.D. inches O.D. mm
TPE insulation 580-080-400 4 0.65 16.5
Color code: 6AWG (16.00 mm²) Stranding: VDE 0295, class 6 (512 x 0.20 mm)
black conductors with white Part Numbers cond. O.D. inches O.D. mm Part Numbers cond. O.D. inches O.D. mm
numbers 1, 2, 3 plus one ground 580-060-400 4 0.76 19.2
wire green/yellow 4AWG (25.00 mm²) Stranding: VDE 0295, class 6 (800 x 0.20 mm)
Part Numbers cond. O.D. inches O.D. mm Part Numbers cond. O.D. inches O.D. mm
Stranding: 580-040-400 4 0.95 24.1
cores twisted in layers 2AWG (35.00 mm²) Stranding: VDE 0295, class 6 (1120 x 0.20 mm)
with fleece around the cores Part Numbers cond. O.D. inches O.D. mm Part Numbers cond. O.D. inches O.D. mm
Jacket: 580-020-400 4 1.08 27.5
PUR jacket black 1AWG (50.00 mm²) Stranding: VDE 0295, class 6 (705 x 0.30 mm)
flame retardant and self- Part Numbers cond. O.D. inches O.D. mm Part Numbers cond. O.D. inches O.D. mm
extinguishing 580-010-400 4 1.42 36.0
UV resistant
Technical Data:
Rated voltage:
1,000 volt
Test voltage:
4,000 volt
Bending radius:
fixed: 5 x diameter
flexible app.: 5 x diameter
Temperature range:
fixed: -22°F to 176°F
flex.: -22°F to 176°F


Sheet 4: G-F-07

CC-Servo Motor-supply PUR-C-581
with filler if necessary Superflex halogen-free shielded
Applications: 16AWG (1.50 mm²) Stranding: VDE 0295, class 6 (84 x 0.15 mm)
Servo Motors Part Numbers cond. O.D. inches O.D. mm Part Numbers cond. O.D. inches O.D. mm
Power supply chains 581-0015-004 4 0.36 9.0
handling equipments 14AWG (2.50 mm²) Stranding: VDE 0295, class 6 (140 x 0.15 mm)
Oil and hydrolysis resistant Part Numbers cond. O.D. inches O.D. mm Part Numbers cond. O.D. inches O.D. mm
high mechanical stress 581-0025-004 4 0.43 10.7
Specifications: 12AWG (4.00 mm²) Stranding: VDE 0295, class 6 (224 x 0.15 mm)
According to VDE Part Numbers cond. O.D. inches O.D. mm Part Numbers cond. O.D. inches O.D. mm
0245, 0281 581-0040-004 4 0.48 12.2
10AWG (6.00 mm²) Stranding: VDE 0295, class 6 (192 x 0.20 mm)
Construction: Part Numbers cond. O.D. inches O.D. mm Part Numbers cond. O.D. inches O.D. mm
Conductors: 581-0060-004 4 0.56 14.0
Fine bare copper strands acc. 8AWG (10.00 mm²) Stranding: VDE 0295, class 6 (320 x 0.20 mm)
to VDE 0295, class 6, with Part Numbers cond. O.D. inches O.D. mm Part Numbers cond. O.D. inches O.D. mm
TPE insulation 581-0100-004 4 0.69 17.3
Color code: 6AWG (16.00 mm²) Stranding: VDE 0295, class 6 (512 x 0.20 mm)
black conductors with white Part Numbers cond. O.D. inches O.D. mm Part Numbers cond. O.D. inches O.D. mm
numbers 1, 2, 3 plus one ground 581-0160-004 4 0.80 20.2
wire green/yellow 4AWG (25.00 mm²) Stranding: VDE 0295, class 6 (800 x 0.20 mm)
Stranding: Part Numbers cond. O.D. inches O.D. mm Part Numbers cond. O.D. inches O.D. mm
cores twisted in layers 581-0250-004 4 0.98 24.9
with fleece around the cores 2AWG (35.00 mm²) Stranding: VDE 0295, class 6 (1120 x 0.20 mm)
and special bandage Part Numbers cond. O.D. inches O.D. mm Part Numbers cond. O.D. inches O.D. mm
Jacket: 581-0350-004 4 1.13 28.7
PUR jacket gray 1AWG (50.00 mm²) Stranding: VDE 0295, class 6 (705 x 0.30 mm)
flame retardant and self- Part Numbers cond. O.D. inches O.D. mm Part Numbers cond. O.D. inches O.D. mm
extinguishing 581-0500-004 4 1.43 36.2
Technical Data:
Rated voltage:
500/1,000 Volt
Test voltage:
4,000 volt
Bending radius:
fixed: 5 x diameter
flexible app.: 7.5 x diameter
Temperature range:
fixed: -22°F to 176°F
flex.: -22°F to 176°F


Sheet 5: G-F-09

CC-Servo Motor-supply PUR-C-581-UL
with filler if necessary Superflex halogen-free shielded
Applications: 16AWG (1.50 mm²) Stranding: VDE 0295, class 6 (84 x 0.15 mm)
Servo Motors Part Numbers cond. O.D. inches O.D. mm Part Numbers cond. O.D. inches O.D. mm
Power supply chains 581-160-408 4 0.44 11.1
handling equipments 14AWG (2.50 mm²) Stranding: VDE 0295, class 6 (140 x 0.15 mm)
Oil and hydrolysis resistant Part Numbers cond. O.D. inches O.D. mm Part Numbers cond. O.D. inches O.D. mm
high mechanical stress 581-140-408 4 0.47 11.6
Specifications: 12AWG (4.00 mm²) Stranding: VDE 0295, class 6 (224 x 0.15 mm)
According to VDE 0245/0281 Part Numbers cond. O.D. inches O.D. mm Part Numbers cond. O.D. inches O.D. mm
UL style 10264/20235 581-120-408 4 0.52 13.1
CSA style AWM I A/B, II A/B FT 1 10AWG (6.00 mm²) Stranding: VDE 0295, class 6 (192 x 0.20 mm)
Construction: Part Numbers cond. O.D. inches O.D. mm Part Numbers cond. O.D. inches O.D. mm
Conductors: 581-100-408 4 0.61 15.4
Fine bare copper strands acc. 8AWG (10.00 mm²) Stranding: VDE 0295, class 6 (320 x 0.20 mm)
to VDE 0295, class 6, with Part Numbers cond. O.D. inches O.D. mm Part Numbers cond. O.D. inches O.D. mm
TPE insulation 581-080-408 4 0.76 19.2
Color code: 6AWG (16.00 mm²) Stranding: VDE 0295, class 6 (512 x 0.20 mm)
black conductors with white Part Numbers cond. O.D. inches O.D. mm Part Numbers cond. O.D. inches O.D. mm
numbers 1, 2, 3 plus one ground 581-060-408 4 0.97 24.5
wire green/yellow 4AWG (25.00 mm²) Stranding: VDE 0295, class 6 (800 x 0.20 mm)
Stranding: Part Numbers cond. O.D. inches O.D. mm Part Numbers cond. O.D. inches O.D. mm
cores twisted in layers 581-040-408 4 1.13 28.7
with fleece around the cores 2AWG (35.00 mm²) Stranding: VDE 0295, class 6 (1120 x 0.20 mm)
and special bandage Part Numbers cond. O.D. inches O.D. mm Part Numbers cond. O.D. inches O.D. mm
Jacket: 581-020-408 4 1.34 34.0
PUR jacket orange 1AWG (50.00 mm²) Stranding: VDE 0295, class 6 (705 x 0.30 mm)
flame retardant and self- Part Numbers cond. O.D. inches O.D. mm Part Numbers cond. O.D. inches O.D. mm
extinguishing 581-010-408 4 1.59 40.3
UV resistant
Technical Data:
Rated voltage:
1,000 Volt
Test voltage:
4,000 volt
Bending radius:
fixed: 5 x diameter
flexible app.: 7.5 x diameter
Temperature range:
fixed: -22°F to 176°F
flex.: -22°F to 176°F


Sheet 6: G-F-15

CC-Servo Motor-supply PUR-C-582-UL
with filler if necessary
Applications:
Power supply chains Superflex power/data shielded
handling equipments Power 19AWG (0.75 mm²) Stranding: VDE 0295, class 6 (42 x 0.15 mm)
Oil and hydrolysis resistant Data 22AWG (0.34 mm²) Stranding: VDE 0295, class 6 (42 x 0.10 mm)
high mechanical stress Part Numbers power cond. shld. pairs O.D inches O.D. mm
Specifications: 582-4007-2203-08 4 x 19AWG 2 pairs 22AWG 0.44 11.0
According to VDE 0245/0281
UL style 10264/20234 Power 18AWG (1.00 mm²) Stranding: VDE 0295, class 6 (56 x 0.15 mm)
CSA style AWM I A/B, II A/B FT 1 Data 19AWG (0.75 mm²) Stranding: VDE 0295, class 6 (42 x 0.15 mm)
Construction: Part Numbers power cond. shld. pairs O.D inches O.D. mm
Conductors: 582-4010-2207-08 4 x 18AWG 2 pairs 19AWG 0.48 12.0
Fine bare copper strands acc.
to VDE 0295, class 6, with Power 16AWG (1.50 mm²) Stranding: VDE 0295, class 6 (84 x 0.15 mm)
TPE insulation Data 20AWG (0.50 mm²) Stranding: VDE 0295, class 6 (28 x 0.15 mm)
Color code: Part Numbers power cond. shld. pairs O.D inches O.D. mm
black conductors with white 582-4015-2205-08 4 x 16AWG 2 pairs 20AWG 0.48 12.1
numbers 1, 2, 3 plus one ground
wire green/yellow, pairs numb. Power 16AWG (1.50 mm²) Stranding: VDE 0295, class 6 (84 x 0.15 mm)
Stranding: Data 19AWG (0.75 mm²) Stranding: VDE 0295, class 6 (42 x 0.15 mm)
cores twisted in layers, pairs Part Numbers power cond. shld. pairs O.D inches O.D. mm
shielded with alu foil, drain wire 582-4015-2207-08 4 x 16AWG 2 pairs 19AWG 0.48 12.1
and braided screen, wrapping,
fleece and common shield around Power 14AWG (2.50 mm²) Stranding: VDE 0295, class 6 (140 x 0.15 mm)
all wires Data 16AWG (1.50 mm²) Stranding: VDE 0295, class 6 (84 x 0.15 mm)
Jacket: Part Numbers power cond. shld. pairs O.D inches O.D. mm
PUR jacket orange 582-4025-2215-08 4 x 14AWG 2 pairs 16AWG 0.60 15.1
flame retardant and self-
extinguishing Power 12AWG (4.00 mm²) Stranding: VDE 0295, class 6 (224 x 0.15 mm)
Technical Data: Data 16AWG (1.50 mm²) Stranding: VDE 0295, class 6 (84 x 0.15 mm)
Rated voltage: Part Numbers power cond. shld. pairs O.D inches O.D. mm
1,000 Volt 582-4040-2215-08 4 x 12AWG 2 pairs 16AWG 0.71 17.8
Test voltage:
Power cores 4,000 Volt Power 10AWG (6.00 mm²) Stranding: VDE 0295, class 6 (102 x 0.20 mm)
Control cores 2,000 Volt Data 16AWG (1.50 mm²) Stranding: VDE 0295, class 6 (84 x 0.15 mm)
Bending radius: Part Numbers power cond. shld. pairs O.D inches O.D. mm
fixed: 5 x diameter 582-4060-2215-08 4 x 10AWG 2 pairs 16AWG 0.71 18.0
flexible app.: 7.5 x diameter
Temperature range:
fixed: -22°F to 176°F
flex.: -22°F to 176°F


Sheet 7: G-F-16

CC-Servo Motor-supply PUR-C-582-UL
with filler if necessary
Applications:
Power supply chains Superflex power/data shielded
handling equipments Power 8AWG (10.00 mm²) Stranding: VDE 0295, class 6 (320 x 0.20 mm)
Oil and hydrolysis resistant Data 16AWG (1.50 mm²) Stranding: VDE 0295, class 6 (84 x 0.15 mm)
high mechanical stress Part Numbers power cond. shld. pairs O.D inches O.D. mm
Specifications: 582-4100-2215-08 4 x 8AWG 2 pairs 16AWG 0.44 11.0
According to VDE 0245/0281
UL style 10264/20234 Power 6AWG (16.00 mm²) Stranding: VDE 0295, class 6 (512 x 0.20 mm)
CSA style AWM I A/B, II A/B FT 1 Data 16AWG (1.50 mm²) Stranding: VDE 0295, class 6 (84 x 0.15 mm)
Construction: Part Numbers power cond. shld. pairs O.D inches O.D. mm
Conductors: 582-4160-2215-08 4 x 6AWG 2 pairs 16AWG 1.06 26.8
Fine bare copper strands acc.
to VDE 0295, class 6, with Power 4AWG (25.00 mm²) Stranding: VDE 0295, class 6 (800 x 0.20 mm)
TPE insulation Data 16AWG (1.50 mm²) Stranding: VDE 0295, class 6 (84 x 0.15 mm)
Color code: Part Numbers power cond. shld. pairs O.D inches O.D. mm
black conductors with white 582-4250-2215-08 4 x 4AWG 2 pairs 16AWG 1.15 29.2
numbers 1, 2, 3 plus one ground
wire green/yellow, pairs numb. Power 2AWG (35.00 mm²) Stranding: VDE 0295, class 6 (1120 x 0.20 mm)
Stranding: Data 16AWG (1.50 mm²) Stranding: VDE 0295, class 6 (84 x 0.15 mm)
cores twisted in layers, pairs Part Numbers power cond. shld. pairs O.D inches O.D. mm
shielded with alu foil, drain wire 582-4350-2215-08 4 x 2AWG 2 pairs 16AWG 1.28 32.4
and braided screen, wrapping,
fleece and common shield around Power 1AWG (50.00 mm²) Stranding: VDE 0295, class 6 (705 x 0.30 mm)
all wires Data 14AWG (2.50 mm²) Stranding: VDE 0295, class 6 (140 x 0.15 mm)
Jacket: Part Numbers power cond. shld. pairs O.D inches O.D. mm
PUR jacket orange 582-4500-2225-08 4 x 1AWG 2 pairs 14AWG 1.46 37.0
flame retardant and self-
extinguishing Power 16AWG (1.50 mm²) Stranding: VDE 0295, class 6 (84 x 0.15 mm)
Technical Data: Data 16AWG (1.50 mm²) Stranding: VDE 0295, class 6 (84 x 0.15 mm)
Rated voltage: Part Numbers power cond. shld. pairs O.D inches O.D. mm
1,000 Volt 582-4015-215-08 4 x 16AWG 1 pair 16AWG 0.48 12.0
Test voltage:
Power cores 4,000 Volt Power 14AWG (2.50 mm²) Stranding: VDE 0295, class 6 (140 x 0.15 mm)
Control cores 2,000 Volt Data 16AWG (1.50 mm²) Stranding: VDE 0295, class 6 (84 x 0.15 mm)
Bending radius: Part Numbers power cond. shld. pairs O.D inches O.D. mm
fixed: 5 x diameter 582-4025-215-08 4 x 14AWG 1 pair 16AWG 0.51 12.8
flexible app.: 7.5 x diameter
Temperature range:
fixed: -22°F to 176°F
flex.: -22°F to 176°F


Sheet 8: G-F-17

CC-Servo Motor-supply PUR-C-582-UL
Applications:
Power supply chains Superflex power/data shielded
handling equipments Power 12AWG (4.00 mm²) Stranding: VDE 0295, class 6 (224 x 0.15 mm)
Oil and hydrolysis resistant Data 16AWG (1.50 mm²) Stranding: VDE 0295, class 6 (84 x 0.15 mm)
high mechanical stress Part Numbers power cond. shld. pairs O.D inches O.D. mm
Specifications: 582-4040-215-08 4 x 12AWG 1 pair AWG16 0.57 14.4
According to VDE 0245/0281 Power 10AWG (6.00 mm²) Stranding: VDE 0295, class 6 (192 x 0.20 mm)
UL style 10264/20234 Data 16AWG (1.50 mm²) Stranding: VDE 0295, class 6 (84 x 0.15 mm)
CSA style AWM I A/B, II A/B FT 1 Part Numbers power cond. shld. pairs O.D inches O.D. mm
Construction: 582-4060-215-08 4 x 10AWG 1 pair AWG16 0.69 17.6
Conductors: Power 8AWG (10.00 mm²) Stranding: VDE 0295, class 6 (320 x 0.20 mm)
Fine bare copper strands acc. Data 16AWG (1.50 mm²) Stranding: VDE 0295, class 6 (84 x 0.15 mm)
to VDE 0295, class 6, with Part Numbers power cond. shld. pairs O.D inches O.D. mm
TPE insulation 582-4100-215-08 4 x 8AWG 1 pair AWG16 0.81 20.4
Color code: Power 6AWG (16.00 mm²) Stranding: VDE 0295, class 6 (512 x 0.20 mm)
black conductors with white Data 16AWG (1.50 mm²) Stranding: VDE 0295, class 6 (84 x 0.15 mm)
numbers 1, 2, 3 plus one ground Part Numbers power cond. shld. pairs O.D inches O.D. mm
wire green/yellow, pairs numb. 582-4160-215-08 4 x AWG6 1 pair AWG16 0.92 23.4
Stranding: Power 4AWG (25.00 mm²) Stranding: VDE 0295, class 6 (800 x 0.20 mm)
cores twisted in layers, pairs Data 16AWG (1.50 mm²) Stranding: VDE 0295, class 6 (84 x 0.15 mm)
shielded with alu foil, drain wire Part Numbers power cond. shld. pairs O.D inches O.D. mm
and braided screen, wrapping, 582-4250-215-08 4 x AWG4 1 pair AWG16 1.10 28.0
fleece and common shield around Power 2AWG (35.00 mm²) Stranding: VDE 0295, class 6 (1120 x 0.20 mm)
all wires Data 16AWG (1.50 mm²) Stranding: VDE 0295, class 6 (84 x 0.15 mm)
Jacket: Part Numbers power cond. shld. pairs O.D inches O.D. mm
PUR jacket orange 582-4350-215-08 4 x AWG2 1 pair AWG16 1.27 32.3
flame retardant and self- Power 1AWG (50.00 mm²) Stranding: VDE 0295, class 6 (705 x 0.30 mm)
extinguishing Data 16AWG (1.50 mm²) Stranding: VDE 0295, class 6 (84 x 0.15 mm)
Technical Data: Part Numbers power cond. shld. pairs O.D inches O.D. mm
Rated voltage: 582-4500-215-08 4 x AWG1 1 pair AWG16 1.39 35.3
1,000 Volt
Test voltage:
Power cores 4,000 Volt
Control cores 2,000 Volt
Bending radius:
fixed: 5 x diameter
flexible app.: 7.5 x diameter
Temperature range:
fixed: -22°F to 176°F
flex.: -22°F to 176°F